MNP37M03GBV00 Date: 24-11 Rev. 0
Page 12 of 79
4.2.2.- Connection to mains.
~
The machine is set up to work with a single-phase voltage of 230 V, 50 Hz.,
protected with 10 A and 16 A fuses.
Before connecting the machine to mains, please make sure that mains voltage
coincides with the data which appear on the machine ID label (which is affixed to the
inside of the machine door) with variations under ±6%.
- The supply line should be appropriate for the distributor’s usage needs.
- Use a ground leakage protection system.
- Position the machine so the mains socket is accessible.
The mains socket should be compatible with the machine’s plug. If it is not, it should
be replaced with a compatible socket.
The connection should include a grounding connection in compliance with
regulations.
F
It is very important that the electrical circuit has an appropriate ground
connection which meets current regulations. If in doubt, have a qualified
technician check the installation.
The machine is supplied with a power supply cable, type
H05VV-F 3x1,5 mm
²
with a SCHUKO plug.
Do not use adapters, extension cords or multiple socket devices.
Before powering the machine, make sure that you have connected the machine to
water mains and that the
stopcock is open.
Jofemar S. A.
does not assume any liability should the above instructions not be
headed in whole or in part.