7 Description of Connections
52
Jetter AG
7.3
Servo Motor
Specification of Terminal X1
• 8-pin screw clamping terminal (type MC 1.5/ 8-ST-3.5)
• Diameter of the cable apt for connecting: 0.14 - 1.5 mm
2
with bootlace ferrules and plastic sleeve: 0.25 - 1 mm
2
• Bladed screw-driver: 0.4 x 2.5 mm
• Stud torque for the screw clamping terminal: 0.22 Nm
Specification of the Motor Cable
• Cable size: 4 * 1.00 mm²
• Material: Copper
• Temperature class: 60 °C
• Stripping length of cores: 6 mm
• Cable shielding: Braided copper shield of 80 % coverage min.
• Maximum cable length: 50 m
As of a line length of 40 m, we recommend using a motor line reactor at the JM-
105 (see "Motor line reactor to be mounted on the DIN rail, screwing connection",
page 93)
Motor connection
Terminals X1 on the
amplifier side
Signal
Specification
U2
Motor phase 1
Motor cable
V2
Motor phase 2
Motor cable
W2
Motor phase 3
Motor cable
BALLAST
Ballast resistor
An optional ballast resistor can be
connected between this terminal and
ground.
PE
PE conductor
The PE conductor is connected to
the enclosure.
Summary of Contents for JM-105
Page 1: ...User Manual JM 105 Digital Servo Amplifier 60872838 We automate your success...
Page 10: ...Table of Contents JetWeb 10 Jetter AG...
Page 21: ...JetMove 105 2 2 Mechanical Installation Jetter AG 21 Fig 3 Recommended mounting m i n 2 5 m m...
Page 26: ...2 Installing the JetMove 105 26 Jetter AG...
Page 32: ...3 Operating Conditions 32 Jetter AG...
Page 34: ...4 Physical Dimensions 34 Jetter AG...
Page 40: ...5 Technical Specifications 40 Jetter AG...
Page 84: ...7 Description of Connections 84 Jetter AG...
Page 96: ...11 Ordering Information 96 Jetter AG...
Page 97: ...JetMove 105 Appendices Jetter AG 97 Appendices...
Page 98: ...Appendices 98 Jetter AG...