5 Technical Specifications
36
Jetter AG
Leakage current
< 0.1 mA at a cable length of 3 m.
The leakage current increases at increasing
cable length.
The 0 V connection is connected to earth by
a resistor of 400 k
and a capacitor of
75 nF.
Voltage supply of processor logics
(demands on power supply
module)
• 24 V DC (12 ... 40 V)
250 mA at 24 V
Additonally: 500 mA for digital output
Additonally: 300 mA for encoder supply
at X61
• The voltage output has to comply with
the power supply unit of the SELV or
PELV type.
Inrush current limitation of the
processor logics
The JM-105 is equipped with an internal
200 µF capacitors for buffering.
The inrush current is not limited.
Enable1/2,
reference switch (REF),
positive limit switch (Limit+),
negative limit switch (Limit-),
and Input (Inp)
• DC 24 V (14 ... 32 V) related to the
controller potential
• Input current of 8 mA max. each
• Refer to: chapter 7.10 "Digital and
Analog Inputs and Outputs", page 80
Brake circuit (X62:2)
Can be switched by the application program
of the PLC or automatically at enable of the
motor current.
24 V DC (+V
log
- 0.5 V)
I
max.
= 0.5 A
Contact: Semiconductor switch (NOC with
integrated free-wheeling diode and short-
circuit monitoring)
Connect this pin only to devices that are
related to the same potential as the power
supply of the controller logic.
Encoder supply (X61:1 and 6)
• Encoder supply voltage:
5 V DC +/-5 %, max. 350 mA
• Encoder supply voltage:
24 V DC (+Vl
og
- 0.5 V), max. 300 mA
Resolver inputs
• Resolver excitation: 8 Vpp
• Frequency: 8 kHz
• Input impedance: 30 k
SinCos encoder inputs
• 1 Vpp differential signals
• max. frequency:
analog 450 kHz, digital 5 MHz
• Input impedance: 30 k
Electrical Specification
Ω
Ω
Ω
Summary of Contents for JM-105
Page 1: ...User Manual JM 105 Digital Servo Amplifier 60872838 We automate your success...
Page 10: ...Table of Contents JetWeb 10 Jetter AG...
Page 21: ...JetMove 105 2 2 Mechanical Installation Jetter AG 21 Fig 3 Recommended mounting m i n 2 5 m m...
Page 26: ...2 Installing the JetMove 105 26 Jetter AG...
Page 32: ...3 Operating Conditions 32 Jetter AG...
Page 34: ...4 Physical Dimensions 34 Jetter AG...
Page 40: ...5 Technical Specifications 40 Jetter AG...
Page 84: ...7 Description of Connections 84 Jetter AG...
Page 96: ...11 Ordering Information 96 Jetter AG...
Page 97: ...JetMove 105 Appendices Jetter AG 97 Appendices...
Page 98: ...Appendices 98 Jetter AG...