Instruction manual JetCat-PRO engines, 1.7 - V12.01V
Special Functions
Temperature calibration
After a replace of a temperature sensor (EGT sensor) it might be necessary to run a temperature calibration
The engine must be at ambient temperature (approx. 21°C)!
Press and hold the „Select Menu“ key on GSU
, then
switch on ECU
(receiver). Instead of „Select Menu“key of GSU, it’s
possible to press the little key on the LED-board.
The LED´s indicate the following blink sequence:
LED
Blink Sequence
Standby
(yellow)
Pump running
(red)
OK
(green)
The display of GSU indicates simultaneously:
Release Key to
„Learn RC“
While this sequence hold the key „SelectMenu“ don’t release it !!!!
Release the key if the three LED´s indicate this blink sequence:
LED
Blink Sequence
Standby
(yellow)
Pump running
(red)
OK
(green)
The display of the GSU indicate simultaneously:
“Release Key to Calibrate Temp“
after releasing the key on the GSU the temperature calibration is executed.