The INFO Menu
Info menu displays the following information:
Value
Explanation
Rest Fuel
Remaining fuel in tank. Tank size can be entered using the
LIMITs
menu. Value is reset
every time the ECU is switched on (or can be reset manually by pressing the
Change
Value/Item
button on the GSU).
Fuel Flow ml/min
Actual fuel consumption in ml/min.
BattCnd
Ubattery
The condition of the battery is indicated in the upper line:
1.
--OK--
2.
!WEAK!
3.
--EMPTY--
1.
If the battery voltage is 1.1V/Cell or higher “
—OK--
“ will be displayed.
2.
If the battery voltage drops under 1.1V/Cell, the display will read “
!WEAK!”
. Red
Standby/Manual
and green
OK
LED’s will blink simultaneously (at a rate of twice
per second). Starting the engine is not possible, until the battery is recharged. If the
engine is already running and the battery warning function is enabled, the warning
function will be activated.
3.
If the battery voltage drops under 1.0V/Cell “—
EMPTY--
”
is displayed. Starting the
engine is not possible until the battery is recharged. If the engine is running, it will
be immediately shut off, to avoid a malfunction of the ECU.
Current voltage of the battery. Displayed on bottom line.
Baro
Temp
Indicate the current barometric pressure.
Temperature indicator (C°) in range of ECU
Last Run Time
Last engine run time.
Last Fuel Count
Quantity of fuel consumed, during the last engine run.
Last-Off PmpVolt
Volts applied to the pump when it was switched off.
Last Off RPM
RPM of the engine, when it was switched off.
Last Off TEMP
Temperature of the engine, when it was switched off.
Last Off Cond
Last stored Off condition.
Last Max Temp
Maximum temperature during the last engine run
Last Min Temp
Minimum temperature during the last engine run
Last AVG Temp
Average temperature during the last engine run
Last MaxR AVGTmp
Average full throttle temperature during the last engine run
Last Max Pump
Maximum pump voltage during the last engine run
Last Min Pump
Minimum pump voltage during the last engine run
Last Avg Pump
Average pump voltage during the last engine run
Last Fail Safe Cnt
Number of Fail Safe during the last engine run
Last Fail Safe Time
Fail Safe Time in seconds
Last-Max AirSpd
Maximum reached flight speed during the last flight
(Only by connected Airspeed sensor!)