3.2 Factory default & basic operation
LED indicators
:
Arm LED :red light up AWAY armed :red blinking HOME armed.
READY LED : light up when system disarm , OFF when system arm
magnetic sensor open.
Power LED -:ON indicates the presence of the AC /DC supply
network.
Alarm LED : Blinking red when the alarm is triggered until the alarm is
cancelled.
STATUS LED -:OFF indicates zone faulty.
.
Basic Settings
The remote control included in the package have been already
enrolled in the control panel and thus ready for operating.
Press *key for 3seconds, then enter administrator password[9876] to
enter system setting. For each menu press # to enter and press return key
to exit. When enter main menu, panel will sound all menu options one
time, then user can press corresponding number or press up, down to
the option you want, then press # to enter setting, then press # or
confirm key to save setting.When hear [setting saved] means setting
successfully otherwise setting failure. The key on numeric keyboard,
numbers for user to enter numbers and [*] for delete, [#] for confirm
Basic Operations
Switching on
: After connecting the AC /DC adapter please turn ON
the batteries switches so the backup battery is automatically recharged.
When turn OFF the panel , please switch OFF the battery switches .
The BAT switches are located at the back of the panel.
Setting the system
: press the [*] and hold for 3 secs +
administrator pa [#] key.
Disarming the system
: User Pa [DISARM]
Voice announcements facilitate and guide the tours of the menu
and submenus selections of system setting . By pressing the "up" and
"Check" Key will move to the next option.
Panic activation
:When the system is disarm press the ALARM key and
hold it for 3 seconds.
BASIC SETTING & OPERATION