![jeiko JKAL300PLUS Manual Download Page 101](http://html.mh-extra.com/html/jeiko/jkal300plus/jkal300plus_manual_641801101.webp)
e46
POWER SOURCES
POWER SOURCES
8. Power sources
1
. The control panel is'powered by an AC/DC adapter and a
rechargeable battery pack integrated into the panel itself
.
2
.In order to preserve the battery during storage a switch disconnects
the rechargeable battery from the alarm control panel. After the
installation, the AC/DC adapter connected to the controller will allow
the battery to charge in 10-12 hours from main power .
3
. The green power LED light indicates the presence of main power.
when the main power is missing the power led is off.
4
.In case of main power failure the rechargeable battery powers up the
control panel. After 30 minutes the control panel notifies the CMS and
the user warning of a blackout.
The low battery status is indicated by the icon on the display.
5.
When the main power is back, the control panel resumes operations
while charging the battery.
6.
In case of main power failure, if the built-in battery is empty or in
case of rechargeable battery replacement , the control panel does not
keep the correct time and therefore it must be reprogrammed again.
The swithing ON operation of the control panel is subjected to
connecting the power supply and the presence of the main power.
7.
When replace the battery of the sensors or detectors :
Shortly before the battery of the wireless sensors runs out its charge,
the sensor sends a signal to the low battery alarm control panel. The
display shows the zone number followed by the digit 8, the battery icon
and alerts you with a voice message each time ARM or DISARM your
alarm system.
When the battery will be fully empty will be displayed on the sensor
number and the status code of L (sensor signal not received).
The same information can apply to the bidirectional sirensr JKAL3ESB
JKAl3EXT , the zone number will be displayed for the siren is 41.