e48
SPECIFICATION
9. Technical Specification
9.1 General Data
!
Power supply:
Builtin rechargeable battery: 11V/1000mAh
Main machine static current: <50mA /12V (exclude wire detector current)
Main machine alarming current: <250mA /12V (exclude high siren current)
!
!
Main machine 12v maximum output current: 100mA for wired detectors
Recording time: 15s
Frequency: 433MHz 0.5MHz
The trigger delay of wired zones: 100 ms
The method of alarming dial: DTMF -GSM
DTMF dial frequency variation :< 1.5%
Communication Protocol with CMS: Ademco Contact ID
9.2 Physical performance:
Area data: 8 wired areas, 32 wireless zones, 8 remote controllers
Zone type: robbing alarm, thief alarm, gas leak alarm, ambulance alarm,
self-defined alarm, fire alarm and boundary alarm events
Frequency: 433MHz
Signal transmit distance: 60 to 100 meters (open area)
Operating st-by time without AC main power : 10 Hours
0
0
0
0
Operation temperature range: 32 F to 120 F (0 C to 45 C)
0
0
0
0
Storage temperature range:-4 F to 140 F (-20 C to 60 C)
0
Relative humidity: 85% at 30 (86 F)
Dimensions: 250*190*48mm
Weight: 550g
Color: gray
+/-5Mhz
adapter 230V/AC 15V DC 1000mA