14
E175 - Item over 99
- Indicates that the buffer used to containing
the operations made in the within of a receipt
it has caught up the 99 lines ; if the receipt it
comes continued, The receipt VOID will not
be more possible and the eventual stub
receipt could not be detailed.
E176 - zero balance obblig.
- Indicates that Sub-Total of the receipt is
negative and that therefore an operation in
order to at least carry such value to "0" (zero)
before to close the operation by a media
Total.
E177 - HALO (RM/VD)
- It indicates that the value of the amount input
for the execution of the VOID or R.M. opera-
tion is upper to the maximum allowed from
the configuration of the ECR.
E178 - LALO (RM/VD)
- It indicates that the value of the amount input
for the execution of the VOID or R.M. opera-
tion is lower to the maximum allowed from
the configuration of the ECR.
E179 - can't mode change
- It indicates that it has been tried to change
the key position with the receipt open ; this
message can appear in mechanical key
moving case (if present like option), or be-
cause the key "key" has been pressed with
the receipt in course.
E180 - subtotal HALO over
- Indicates that it has been exceeded the
maximum amount in one receipt.
E182 - comp. cash declaration
- Cash declaration is compulsory.
E183 - inhibit display report
- It indicates that it is being tried to execute a
report in visualization on the display, while
the ECR is set in order to doesn't allow such
type of report.
E184 - inhibit double multi
- It indicates that it has been executed an
operation of "double multiplication" (Eg.:
10--X--10--X--500) while in the ECR the
operation is not allowed.
E185 - inhibit P-T-D reset
- It indicates that it is being tried to execute a
P-T-D reset while on ECR this kind of reset
isn't allowed.
E186 - no PLU memory
- Indicates that it is being tried to execute an
operation relative to the PLU without reserve
memory space for PLU.
E187 - no PB memory
- Indicates that it is being tried to execute an
operation relative to the PB without reserve
memory space for PB.
E188 - no TMB memory
- Indicates that it is being tried to execute an
operation relative to the TMB without reser-
ve memory space for TMB.
E189 - SLIP not connect
- It indicates that it has been activated the Slip
Printer printing without that the same one is
connected to the ECR or with the Slip Printer
in "OFF" condition.