JA-101K(-LAN)(-LAN3G) and JA-106K(-3G)
Security System Control Panels
9
/
110
MLJ51410
Entering a valid code on the keypad and pressing the green button on the keypad segment is a system
unset. When authorisation and unsetting the system is not performed during the entrance delay then an
alarm from the delay zone will be triggered - from the zone in which the time expires first (Delay A,
delay B, delay C).
1.2
Access codes and their default settings
Authorization is necessary by a valid (4,6 or 8-digit) code or by applying the RFID card or tag
to the authorization module (keypad) to be able to operate the system (setting, unsetting or to check the status
of some section or device). According to the authorization level of the specific user the system shows you all
information and allows system control appropriate to your access rights.
The authorization to control the system with a keypad or to use F-Link (J-Link) software,
the MyJABLOTRON application or the voice menu must be performed by entering a numeric code. The code
can be entered with a prefix (default setting) or without a prefix.
Enter a code with a prefix in the following format:
ppp*cccc
where:
ppp
is the sequential number (position
0 to 300
) of the user (called a prefix)
*
is a separator (* key)
cccc
is a 4,6 or 8-digit code, codes 0000 to 99999999 are allowed
The control panel is delivered with 2 default codes:
Default codes with a prefix
4-digit
6-digit
8-digit
Service
0*1010
0*101010
0*10101010
Administrator
1*1234
1*123456
1*12345678
Caution:
The
service code
has to always begin with a
0
prefix If prefix is selected
The
administrator code
has to always begin with a
1
prefix if prefix is selected
The default codes are filled in automatically by the F-Link software, so from the first activation until a code
change the software does not request them. However for security reasons immediately after installation
is finished, it is imperative to change all default codes. If both codes are not changed, when the Service mode
is exited an SMS is sent to the service phone number, reporting “Warning, default codes, Section 1” (it can
be cancelled in the Parameters “Default codes warning”).
Enter a code with a prefix in the following format:
For systems with a smaller number of users the prefix can be disabled and the system can then be controlled
with four-digit codes only. The prefix can be disabled in the Initial setup tab in F-Link. In that case the Service
and Administrator codes are set as follows:
cccc
where:
cccc
is a 4,6 or 8-digit code, codes 0000 to 99999999 are allowed
Default codes without a prefix
4-digit
6-digit
8-digit
Service
1010
101010
10101010
Administrator
1234
123456
12345678
Warning:
When the Prefix is disabled, the codes will always be changed to the default values (1010 and
1234) and all other codes are erased. All access RFID cards/tags remain. When the Prefix is enabled, all the
codes and cards/tags will remain set and the prefixes will only be added.
1.2.1 Change of access codes
When the option „Code with prefix“ is enabled then the control panel allows the arbitrary digit combination
of a 4 – 8-digit code for every user (they can even have the same code with a different prefix). Every user with
a „User“ authorization and the checked parameter „Code change allowed“ has an option to edit his own code.
Access codes can be changed by:
LCD keypad (PC has to be disconnected from the control panel, no remote or local connection)