JA-101K(-LAN)(-LAN3G) and JA-106K(-3G)
Security System Control Panels
70
/
110
MLJ51410
10.7 PG outputs tab
It is used to set functions of the programmable outputs. The tab will display as many positions as you have
selected in the Initial setup tab. If no outputs are set there (Outputs = 0), the PG outputs tab will
not be displayed at all. To make changes in this tab you do not need to be in the Service mode.
* Items marked this way are displayed if
Advanced Settings
are on
Name
– identification of the output (e.g. Air-conditioning, Warehouse door,...)
Logic
– possibility to set the inverted logic of the output.
Function
– determines behaviour of the output after activation.
Impulse
enables activation with a time limitation (the time is set in the Time button).
ON/OFF
the enabling command will cause activation, disabling command deactivation while
the status of the source or duration is not checked, the last command always
performs its request
Copy
copies activation of a detector or internal status; if there is a request from two
devices, the OR logic is used
Delayed copy
only sends a command when the activation condition is valid longer than set
in the Time column (suitable e.g. for indication of forgotten closing of a garage gate).
Extended copy
copies activation of a device (or internal status) and extends it by the time set
in the Time column (suitable e.g. for lighting of a corridor after door opening).
Change
by activation the current PG status is inverted to the opposite status (only suitable
for impulse control, e.g. with a remote control button).
Time
– setting of time for the functions Impulse, Copy after delay and Copy with overlap. Tim is set
in the format
hh:mm:ss
in the range of 00:00:01 to
23:59:59.
Activation
– Opening the Activation Map of the PG
output – see chapter 10.7.1 Activation Map of a PG
outputs.
Blocking of PG
– makes it possible to block
an output by a section status or detector. The blocking
prevents the particular PG from being enabled and
if it is already on, it will disable it. It is suitable e.g.
to block a door lock if the respective section is set.
In the case of blocking by a section status you can
select whether the blocking is valid when the section
is set or unset and in the case of blocking by a device whether by its activation or deactivation.
Both the blocking options (by a section and device) can be used at the same time.