Notes:
1 – “you are not authorized for this selection” – always if the user is not authorized to handle a section
or check status
2 – “required report of an important message, the call will be terminated in 30 seconds” – reports /
important messages to ARM have priority over the ongoing voice menu
Entry in the recording mode is indicated with a beep. A recorded message is replayed for listening
immediately after recording.
If you are not satisfied with the record, you can select re-recording immediately.
It is suitable to start recording immediately after the beep signal and to press the end character*
immediately after the end of your recording
The installation name may take 40 sec. at the most. Every other message may be 20 sec. long at
the most.
9.6
SMS commands
The system can be controlled with SMS commands. SMS commands can be used to control the setting
statuses of individual sections (setting, unsetting), or just a query about the statuses of individual sections
or other statuses of the whole system. The texts of the command used to control PG outputs are editable,
the other texts cannot be changed. There are no factory commands to control PG outputs, it is necessary to set
them first.
Command structure:
ppp*kkkk_command
where: ppp is the position number of the user code;
*
is a separator (
*
is only necessary if a code with a prefix is used);
nnnn
is a user code;
_ is a separating gap;
command
is the execution command (see list of commands below).
Query commands:
information about the system status can also be obtained with the use of the following commands
DINFO, STATUS, COM and GSM
(the texts of the commands cannot be changed).
Control command:
the control of setting the
system
as a whole or just its individual
sections
can be generated with the use of
the following commands:
SET, UNSET, or SET x x x, UNSET x x x, where x are numbers of sections separated by a
space
(the texts of the commands cannot be changed).
The control commands for the control of
PG
outputs are not pre-set by the manufacturer and if necessary,
they must be set.
Caution:
If control commands include accented diacritics (like with the languages GR and RU), then the
Diacritics parameter on the Communication tab should be enabled for correct and reliable functioning. It is also
necessary to mind small and capital letters when diacritics are enabled. With usual characters size doesn´t
matter.