JA-101K(-LAN)(-LAN3G) and JA-106K(-3G)
Security System Control Panels
44
/
110
MLJ51410
Keypad control segments and bidirectional remote controls have the same way of indication by a three colour
LED. Descriptions of individual statuses are mentioned in the following table:
Bidirectional remote controls (JA-15xJ) status indication – shown 2 sec after being pressed:
LED lights green
Section status Unset or PG output OFF
LED lights yellow
Section status Partially set
LED lights red
Section status Set or PG output ON
LED flashes red
There is an obstacle in the section which prevents setting
LED flashes yellow
Command status unknown (fault of communication, out of communication range)
Using a unidirectional remote control (JA-16xJ) this controls the system the same way and indicates
by its LED that button pressing is indicated and the command sent. There is no feedback from the control panel
and the user should use a different type of status indication to confirm a section status change such as siren
chirps, other optical indications or SMS reports about setting / unsetting.
9.4
System control by a calendar
Automatic system control can be performed by the control panel’s internal calendar. The calendar can be
pre-set to do up to 20 actions (full setting, partial setting, unsetting of selected sections and also switching
ON / OFF or blocking / unblocking of selected PG outputs).
Every action can allow days of the week (from Monday to Sunday) to be pre-set when it can be performed
so only working days or the weekend can be pre-set. For every action it is necessary to select the time and the
particular action to be done and also one event (action) for PG output control. So at a specific hour section(s)
can be set or unset and simultaneously a PG output ON or OFF. A typical application is the automatic setting
of a section in shops, partial setting of a building at night or light control in the night. Every automatic event
is recorded in the history log with the name of the source being “Calendar“.
Calendar control options related to guarding:
Set
It sets pre-set section(s) and starts with an exit beeping time of 180 sec (regardless of how
long the exit time has been set in the control panel), within this time all alarm zones behave
like a delayed zone. A prolonged time of acoustic exit indication is meant for warning users
who is in the protected premises to inform them about the fact that the system has been set
by an automatic timer. During this time the user has to go to the system keypad immediately
and unset the section in the usual way or leave the protected premises. If he would ignore
this warning and stays in the building and keeps moving then an alarm will be triggered.
The control panel fully respects all ways of setting and checking the systems ready to be set
rules.
Set
immediately
It sets pre-set section(s) immediately without an exit delay or any acoustic indication.
The system is set immediately so no movement is possible in the protected premises.
If someone would keep moving in the premises after self-setting performance then an alarm
would be triggered in the set section(s). The option is for fast and silent setting with
no warning. The control panel fully respects all ways of setting and checking the systems
ready to be set rules.
Set partially
It sets pre-set section(s) partially and starts with an exit beeping time of 180 sec
(regardless of how long an exit time has been set in the control panel), within this time all
alarm zones behave like delayed ones. A prolonged time for acoustic exit indication
is meant for warning users who are in the protected premises to inform them about the fact
that the system has been set partially by an automatic timer. Partial setting is not usually
acoustically indicated (See Parameters tab to enable it). The control panel fully respects all
ways of setting and checking the systems ready to be set rules.
Set partially
now
It sets pre-set section(s) partially and immediately without an exit delay or any acoustic
indication. The system is set immediately in the pre-set time. The option is for fast and silent
setting with no warning. The control panel fully respects all ways of setting and checking
the systems ready to be set rules.
Set always
It sets pre-set section(s) and starts with an exit beeping time of 180 sec (regardless of how
long the exit time has been set in the control panel), within this time all alarm zones behave
like a delayed zone. The control panel doesn´t fully respect all ways of setting and checking
the systems ready to be set rules.
Always set
partially
It sets pre-set section(s) partially and starts with an exit beeping time of 180 sec
(regardless of how long the exit time has been set in the control panel), within this time all
alarm zones behave like a delayed zone. The control panel doesn´t fully respect all ways
of setting and checking the systems ready to be set rules.