JABLOTRON
ALARMS
a.s.
Pod
Skalkou
4567/33
46601
Jablonec
n.
Nisou
Czech
Republic
www
.jablotron.com
||
|
JA-101K(-LAN)(-LAN3G) and JA-106K(-3G)
Security System Control Panels
71
/
110
MLJ51410
Reports
– setting the texts of SMS reports sent on activation or deactivation of a PG output. The users that
each of the reports is sent to are set in the Reports to Users tab. When the texts of the reports are changed,
they are recorded in the log, so they cannot be completely deleted.
PG recording in the memory
* – enables registration of PG activation in the event history and thus also SMS
reporting to users and communication to the ARC (e.g. for monitoring the entry of users to monitored doors,
registration in the Web Self Service etc.)
Disable
– possibility to block a PG output. Disabling (blocking) of an output is indicated by a red dot.
The Administrator (using J-Link) and Service Technician (using F-Link) are authorized to disable an output.
Current status
– color-coded information about the current status of a PG output. Green description
corresponds to the green light of the segment; red description corresponds to the red light of the segment.
Test
– possibility to control an output manually from the computer. Depending on the selected function it will
enable (or disable) the particular PG, if it´s not currently blocked.
Note
– makes it possible to describe details of a PG output, its use, special behaviour, notification of activation
together with other outputs etc.
10.7.1 Activation Map of a PG outputs
By selecting Activation in the PG outputs tab you will enter the map of activation links. The map determines
what action the output responds to.
Authorized users
– defines users that are authorized to control the PG output with the requirement
for authorization from a keypad (with segment buttons), from the MyJABLOTRON app or by an SMS command.
The setting is linked to the Users tab.
By user’s authorization at a keypad
– allows you to set up to 2 keypads that activate the PG output by mere
authorization (application of a card/tag or code entry). This function is designed for opening of a door lock
(i.e. no operation of the segment buttons is necessary). This function is only available if the output function
is set to Impulse.
By dialling in from user’s tel. numbers
– defining users that are authorized to activate a PG output
by calling from their phone (phone numbers are entered in the Users tab). Phone numbers used for the ringing