4 Before system installation
Select a hidden place for the control panel (inside the protected area) where mains supply
is available. We recommend protecting the room with the control panel by a detector with
immediate reaction. There must be good GSM signal reception in the location (check with
a phone). Caution, if a possible intruder knows where the control panel is located, there is
a risk of the system being damaged without sending information about the intrusion.
The mains supply of the control panel may only be installed by a person with the required
electrical qualifications. The power supply of the control panel has double safety separation
of the circuits. No protective conductor is connected. During the installation and connection
of the BUS components of the control panel all the power supply of the control panel must
be completely off.
The control unit JA-101K (-LAN) provides power supply terminals to select from 2 type
of power supply voltage networks: ~230 V / 50 Hz and ~110 V / 60 Hz. According
to the type of power supply voltage system, the correct connection terminal and the
corresponding fuse must be used in comply with chapter no. 17 Technical specifications.
1. First consider the arrangement and target setting of the system. Clarify the required control method with
the customer. It is recommended to prepare design documentation for a more complex system.
2. When setting up the elements follow their manuals, the general design principles of fire alarm systems and
instructions provided by the manufacturer during the certification training. If you have any unclear points,
phone the Jablotron consultant.
The manufacturer declines any liability for damage if the system
is installed or set improperly.
3. Prepare the power supply of the control panel – use a suitable cable with double insulation and
a cross-section of 0.75 to 1.5 mm². Voltage surge protection on the control panel mains supply
is recommended. It is also recommended to use a single cable with a circuit breaker (2 A-6 A) and it also
functions as a main switch. Don´t connect any other electrical appliance to this specific circuit, not even
power for external PG outputs or a heating system or any other device related to control panel functions.
4. Attach the control panel straight onto the wall or any other incombustible surface. Ensure there are no metal
objects which could negatively influence transmitting or receiving radio signals (radio module and GSM
communicator). Use the supplied template to prepare holes for fasteners. Put the screws through the upper
holes in the plastic housing to keep it 1 cm from the wall, then hang the control panel housing on it. Also put
an additional screw through the lower hole(s) and screw it in as well to stabilize the position of the control
panel. Tighten all the screws.
1 - Connector for auxiliary modules (phone communicator); 2 - Power supply terminal from the transformer; 3 – LED indicators and
RESET jumper; 4 - BUS terminals; 5 – USB connector; 6 - USB cable connector; 7 – Internal BUS connector for the JA-11xR module;
8 - LAN connector (in LAN version only); 9 - Connectors for tamper switches of the housing; 10 - GSM antenna SMA connector;
11 - SIM card holder; 12 - microSD card holder