26
User Manual
JABLOTRON 100
+
Control panel parameters
4 DIGITS
6 DIGITS
8 DIGITS
“Code with a prefi x”
enabled
=
10
4
= (10.000)
=
10
6
= (1.000.000)
=
10
8
= (100.000.000)
“Code with a prefi x”
and
“Duress access control”
both disabled
=
10
4
– (Number of users – 1)
=
10
6
– (Number of users – 1)
=
10
8
– (Number of users – 1)
“Code with a prefi x”
disabled;
“Duress access
control”
enabled
≤
10
4
– ((Number of users
– 1) * 3)
≤
10
6
– ((Number of users
– 1) * 3)
≤
10
8
– ((Number of users
– 1) * 3)
CODE
AUTHORIZATION
TYPE DESCRIPTION
User code
This code has access to sections and PG control rights assigned by an Administrator.
Users can add/delete their RFID tags and access cards and change their own
telephone numbers. Users can change their codes provided that the system uses
Codes with prefixes. It has permission to erase the alarm memory in assigned sections.
Selected users may have their access to sections limited by a schedule.
The number of User codes is limited only by remaining capacity of the control
panel. There is no code set by the factory defaults.
Set code
This code is allowed only to set a designated section and is allowed to control (ON/
OFF) PG outputs which require authorization. Users with this level of authorization are
not allowed to change their code and are not allowed to erase the alarm memory.
The number of Set codes is limited only by remaining capacity of the control
panel. There is no code set by the factory defaults.
PG only code
This code allows the user to control programmable outputs with authorization only.
This applies to both switching on and off. Users with this level of authorization are not
allowed to change their code and are not allowed to erase the alarm memory.
The number of PG only codes is limited only by remaining capacity of the
control panel. There is no code set by the factory defaults.
Panic code
This code is allowed only to trigger Panic alarm. A user of this code is not allowed to
change it or erase the alarm memory.
The number of Panic codes is limited only by remaining capacity of the control
panel. There is no code set by the factory defaults.
Guard code
This is a code for a security agency. This level of authorization allows to set the whole
system. However, the guard code can unset the system only during alarm or after it
expired as long as the alarm memory is still active. A user of this code is not allowed to
change it or erase the alarm memory.
The number of Guard codes is limited only by remaining capacity of the control
panel. There is no code set by the factory defaults.
Unblocking
code
This code is designated to unblock the system after System blocking by alarm.
A user of this code is not allowed to change it or erase the alarm memory.
The number of Unblocking codes is limited only by remaining capacity of the
control panel. There is no code set by the factory defaults.
The security of access codes, contactless RFID devices and remote controls:
A control panel enables each user to be assigned with one 4, 6 or 8-digit code and up to two RFID
tags for system authorization. User authorization is required during each manipulation operation
via keypad, voice menu, a computer, web or mobile apps. Code length affects number of possible
combinations and therefore code security.