2.2.1.   OPERATING THE SYSTEM USING THE MyJABLOTRON 

SMARTPHONE APP

Once a user account is created, the user can remotely monitor and control the system via 
the MyJABLOTRON app for Android and iOS smartphones.

2.2.2.   OPERATING THE SYSTEM VIA THE MyJABLOTRON WEB INTERFACE

The JABLOTRON 100

+

 system can be easily and conveniently operated using your computer via the 

internet and the MyJABLOTRON web interface, which is accessible from 

www.myjablotron.com

.

2.2.3.   OPERATING THE SYSTEM USING THE VOICE MENU

The system can be controlled from a phone through a voice menu, which guides the user through 
a series of options in the preconfi gured language. To access the voice menu, you just dial the alarm 
system’s phone number.

Access to the voice menu can be enabled either to all telephone numbers without restrictions 
or alternatively only to authorized phone numbers stored in the control panel. Depending on 
the confi guration, authorization by entering a valid code on a phone keypad may be required. 
When the user enters the menu, the system will give an update of the current status of all sections 
assigned to the user. The caller then can control these sections, either individually or collectively, 
using phone keypad and available menu options. 

The system default is set up to answer incoming calls after three rings (approximately 15 seconds).

2.2.4.   OPERATING THE SYSTEM USING SMS COMMANDS

SMS commands can control individual sections and programmable outputs just like keypad 
segment buttons. The form of text message to operate the system is: CODE_COMMAND. 
The actual commands are predefi ned (SET/UNSET) with an additional numeric parameter which 
identifi es a specifi c section. One SMS can control multiple sections at the same time. In this case, 
added numbers in the command defi ne sections.

Example of an SMS command used to set sections 2 and 4.

CODE_SET_2_4

The commands to control the programmable outputs can be programmed by a system installer. 
For example, you may choose BLINDS DOWN as your command to close the blinds on your 
windows. It is also possible to confi gure the system not to require a code before a command. 
In such case the command is simply automatically identifi ed when the system recognizes the user’s 
phone number from which the SMS was sent. Confi guration is done by a service technician.

2.2.5.   OPERATING THE SYSTEM REMOTELY USING A COMPUTER 
           

 

(J-LINK)

The JABLOTRON 100

+

 system can be operated remotely using a computer with an installed J-Link 

software. It can be downloaded from the 

www.myjablotron.com

 website.

2.2.6.    CONTROLLING THE PROGRAMMABLE OUTPUTS (PG)

2.2.6.1.   KEYPAD SEGMENT

A PG output switches on by pressing the right button of the segment and switches off by pressing 
the left button. If the output is confi gured as a pulse output, it is switched off according 
to the pre-set time. PG control may or may not be stored in the control panel’s event memory. 
Confi guration is done by a service technician.

Authorization is/is not demanded based on the system confi guration.

Summary of Contents for 100+

Page 1: ...irja ruikershandleiding Brukermanual Instrukcja u ytkownika Manual de Ut nv ndarmanual Manu l Brugermanual K ytt ohjekirja Haszn lati Utas Brukermanual Instrukcja u ytkownika Manual de Utilizador U va...

Page 2: ...JABLOTRON 100...

Page 3: ...WEB INTERFACE 39 2 2 3 OPERATING THE SYSTEM USING THE VOICE MENU 39 2 2 4 OPERATING THE SYSTEM USING SMS COMMANDS 39 2 2 5 OPERATING THE SYSTEM REMOTELY USING A COMPUTER J LINK 39 2 2 6 CONTROLLING TH...

Page 4: ...nce mode no alarms will be triggered in the selected sections including opening or removing the detectors from the installation The maintenance mode is indicated by the activation button ashing green...

Page 5: ...l and there is no code set by the factory defaults Service code Service This code can enter Service mode and configure the system s behavior It has access to all tabs with options including ARC commun...

Page 6: ...is level of authorization are not allowed to change their code and are not allowed to erase the alarm memory The number of PG only codes is limited only by remaining capacity of the control panel Ther...

Page 7: ...JABLOTRON smartphone application Computer via the MyJABLOTRON web interface Telephone using the voice menu Telephone via SMS Computer via the internet using the J Link software Dialling in from an aut...

Page 8: ...rol the system using segments and authorization using either a code the contactless method RFID card tag both code and card tag for higher security or by authorizing and using the options available on...

Page 9: ...code can consist of up to eleven digits a pre x one to three digits an asterisk which separates the pre x and main code and a 4 6 or 8 digit code depending on con guration for example 123 12345678 or...

Page 10: ...list of all detectors indicating system faults from sections to which the user has access rights Displays a list of all blocked detectors in sections to which a user has access rights Shows system st...

Page 11: ...he desired behavior of the system 2 1 2 2 ALARM UNSETTING Note If the Unset section by authorization only during entrance delay parameter is enabled then mere authorization will unset such section whe...

Page 12: ...1 to the last number in a valid code Example for a code with the pre x Valid code 2 9999 Code for unsetting under duress 2 9990 Example for a code without the pre x Valid code 9999 Code for unsetting...

Page 13: ...g indication Indication of a triggered tamper alarm can be terminated only by a Service technician or Administrator Note When using the EN 50131 1 grade 2 system pro le it is always necessary to rst a...

Page 14: ...de or RFID tag card CANCEL WARNING INDICATION SECTION CONTROL PG CONTROL EVENT MEMORY SETTING PREVENTED FAULTS IN SYSTEM BYPASSED DETECTORS SYSTEM STATUS SETTINGS DISPLAY SETTING MAINTENANCE MODE Allo...

Page 15: ...ter the exit delay has expired then the control panel will unset again Unsuccessful setting is indicated by a system indicator ashing yellow reported to the ARC and indicated by an external siren appl...

Page 16: ...tors will not trigger the alarm when somebody moves inside the section 1 When you enter the building triggering a detector with a De layed zone reaction the system starts indicating an entrance delay...

Page 17: ...he status indicator and the function button rapidly ashing red You need to authorize yourself using the keypad in order to terminate the alarm The section remains set a rapidly ashing red function but...

Page 18: ...a device is triggered It is necessary to con rm setting by pressing the lock button again A set section will be con rmed by a red LED light The keyfob buttons can be blocked to prevent accidental pres...

Page 19: ...commands can control individual sections and programmable outputs just like keypad segment buttons The form of text message to operate the system is CODE_COMMAND The actual commands are prede ned SET...

Page 20: ...G is shown by a PG number in a rectangle fi lled with black colour Press ESC to exit the menu 2 2 6 4 REMOTE CONTROL By pressing an assigned button of a remote control Bi directional remote controls c...

Page 21: ...Link software by clicking on the detector in the Settings Diagnostics Disabled column A blocked detector is marked with a yellow circle until it is turned back on using the same procedure A device can...

Page 22: ...change must be saved by selecting Save when the system prompts with Save Settings The system administrator and the service technician can add modify or delete a user phone number or change a user name...

Page 23: ...supply 110 230 V 50 60 Hz max 0 28 A with fuse F1 6 A 250 V Protection class II 110 230 V 50 60 Hz max 0 85 A with fuse F1 6 A 250 V Protection class II Back up battery 12 V 2 6 Ah lead gel 12 V 7 to...

Page 24: ...g date and time Power supply unit Type A according to EN 50131 6 T 031 note In case of a main power failure is the system backed up for 24 hours and at the same time is a failure report sent to the AR...

Page 25: ...SCAN ME...

Page 26: ...www jablotron com M ENJA100 USER...

Reviews: