2.1.3.1. ALARM SETTING
While setting the alarm, if any detector is triggered (e.g. an open window) the system will react
(based on the system confi guration) in one of the following ways:
:: The control panel will set itself. Triggered detectors will be blocked automatically.*)
:: The system will optically indicate triggered detectors with a function button fl ashing red for
8 seconds and the control panel will set automatically once this period has expired (triggered
detectors will be blocked). *)
:: Setting the section with triggered detectors is also possible by pressing the function button
repeatedly. The user must confi rm an intention to set the section with a triggered detector
(e.g. an opened window). Otherwise the system will not set.
:: A triggered detector will prevent the section from being set. This status is optically indicated by
a function button fl ashing red. The detector preventing setting will be shown on the LCD display
menu.
*)
WARNING
: Options a) and b) are not supported by EN 50131, gr.2 (selected control panel
system profi le).
If a detector with the “Instant zone alarm” reaction is triggered
during an exit delay or if a detector with the “Delayed zone
alarm” reaction stays triggered after the exit delay has expired,
then the control panel will unset again. Unsuccessful setting is
indicated by a system indicator fl ashing yellow, reported to the
ARC and indicated by an external siren (applies to the security
Grade 2).
If the control panel is confi gured to be set without authorization
then it is not necessary to authorize yourself. All you have to
do is press a function button of a particular section. It is also
possible to confi gure the control panel to be set simply by
authorization.
WARNING
: Setting without authorization automatically lowers the maximum security level to Grade
1. Consider all possible risks related to using this function.
Consult the installation with a project consultant or a service technician in order to program the
desired behavior of the alarm system.
1. Authorize yourself using
the keypad. Function buttons A, B,
C, D will light up and the system
indicator starts fl ashing green.
2. Press the function
button to set
a particular section. It is possible to
set more sections subsequently.
The delay between sections
selection must not be longer than
2 seconds.
3. The command is executed
and the keypad acoustically indicates
the exit delay. The section is set now,
only the detectors with a “Delayed
Zone” reaction provide time to leave
the guarded area during the Exit delay.
The status indicator and a function
button of the set section will turn red.