2.    OPERATING THE JABLOTRON 100

+

 SYSTEM

The security system can be controlled in a number of different ways. To unset the alarm, 
authorization in the form of user identifi cation is always required. The system detects the identity of 
the users and allows them to operate those parts of the system which they have been assigned to 
control. You can choose from different ways of setting with or without authorization. When Standard 
authorization type is used, you don’t have to authorize yourself because it is possible to set the 
system just by pressing the right segment button on a keypad. The user name, date, and time are 
recorded and stored in the system memory every time the system is accessed. This information is 
available indefi nitely. Any user can also cancel a triggered alarm (stop sirens from sounding) just by 
authorization in any part of the system (depending on their access rights). However, that does not 
automatically unset the system (unless the system’s default setting is changed).

Note

: Depending on the confi guration of the installation and system settings, some of the options 

described below may not be available. Consult the confi guration of the installation with your service 
technician.

Users and their access rights

CODE 
AUTHORIZATION

TYPE DESCRIPTION

ARC code

This code has the highest level of authorization to configure the system’s behavior and 
is exclusively allowed to perform the system unblock after a triggered alarm. 
It can enter Service mode, access all tabs with options including ARC communication 
to which it can deny access to a Service technician (Service code). As long as the 
“Administrator-restricted Service/ARC right” parameter remains unchecked, the ARC 
code can control all sections and PG outputs used in the system. This code enables 
to add more Administrators and other users with a lower level of authorization assign 
them with codes, RFID tags and cards. It also has a permission to erase alarm and 
tamper alarm memory.

The number of ARC codes is limited only by remaining capacity of the control 
panel and there is no code set by the factory defaults.

Service code

(Service)

This code can enter Service mode and configure the system’s behavior. It has access 
to all tabs with options including ARC communication unless the access is limited 
by the ARC technician. As long as the “Administrator-restricted Service/ARC right” 
parameter remains unchecked, the Service code can control all sections and PG 
outputs used in the system. It can create users with ARC permission, other Service 
technicians, Administrators and other users with a lower level of authorization and 
assign them with access codes, RFID tags and cards. It also has a permission to 
erase alarm and tamper alarm memory. The number of Service codes is limited only by 
remaining capacity of the control panel.

By the factory defaults, the code is 1010. The Service user is always on 
position 0 in the control panel and it cannot be erased.

Administrator 

code

(Main)

This code has always full access to all sections and is authorized to control all PG 
outputs. The Administrator can create other Administrator and other codes with 
a lower level of authorization and assign them with access to sections and PG outputs, 
access codes, RFID chips and cards. This code has permission to erase the alarm 
memory. There can be only one main Administrator code which can’t be erased. 
When “Administrator-restricted Service/ARC right” is enabled, the administrator code 
must be authorized to confirm access for ARC and Service technicians.

By the factory defaults, the code is 1234. The main Administrator user 
is always on position 1 and it cannot be erased.

Administrator 

code

(Other)

This code has access to sections selected by the main Administrator to which the other 
Administrator can add new users with the same or lower level of authorization to control 
sections and PG outputs, assign them with access codes, RFID tags and cards. This code 
has permission to erase the alarm memory in assigned sections. When “Administrator-
restricted Service/ARC right” is enabled, the administrator code must be authorized to 
confirm access for ARC and Service technicians. The number of Administrator codes (other) 
is limited only by remaining capacity of the control panel.

There is no code set by the factory defaults.

Summary of Contents for 100+

Page 1: ...irja ruikershandleiding Brukermanual Instrukcja u ytkownika Manual de Ut nv ndarmanual Manu l Brugermanual K ytt ohjekirja Haszn lati Utas Brukermanual Instrukcja u ytkownika Manual de Utilizador U va...

Page 2: ...JABLOTRON 100...

Page 3: ...WEB INTERFACE 39 2 2 3 OPERATING THE SYSTEM USING THE VOICE MENU 39 2 2 4 OPERATING THE SYSTEM USING SMS COMMANDS 39 2 2 5 OPERATING THE SYSTEM REMOTELY USING A COMPUTER J LINK 39 2 2 6 CONTROLLING TH...

Page 4: ...nce mode no alarms will be triggered in the selected sections including opening or removing the detectors from the installation The maintenance mode is indicated by the activation button ashing green...

Page 5: ...l and there is no code set by the factory defaults Service code Service This code can enter Service mode and configure the system s behavior It has access to all tabs with options including ARC commun...

Page 6: ...is level of authorization are not allowed to change their code and are not allowed to erase the alarm memory The number of PG only codes is limited only by remaining capacity of the control panel Ther...

Page 7: ...JABLOTRON smartphone application Computer via the MyJABLOTRON web interface Telephone using the voice menu Telephone via SMS Computer via the internet using the J Link software Dialling in from an aut...

Page 8: ...rol the system using segments and authorization using either a code the contactless method RFID card tag both code and card tag for higher security or by authorizing and using the options available on...

Page 9: ...code can consist of up to eleven digits a pre x one to three digits an asterisk which separates the pre x and main code and a 4 6 or 8 digit code depending on con guration for example 123 12345678 or...

Page 10: ...list of all detectors indicating system faults from sections to which the user has access rights Displays a list of all blocked detectors in sections to which a user has access rights Shows system st...

Page 11: ...he desired behavior of the system 2 1 2 2 ALARM UNSETTING Note If the Unset section by authorization only during entrance delay parameter is enabled then mere authorization will unset such section whe...

Page 12: ...1 to the last number in a valid code Example for a code with the pre x Valid code 2 9999 Code for unsetting under duress 2 9990 Example for a code without the pre x Valid code 9999 Code for unsetting...

Page 13: ...g indication Indication of a triggered tamper alarm can be terminated only by a Service technician or Administrator Note When using the EN 50131 1 grade 2 system pro le it is always necessary to rst a...

Page 14: ...de or RFID tag card CANCEL WARNING INDICATION SECTION CONTROL PG CONTROL EVENT MEMORY SETTING PREVENTED FAULTS IN SYSTEM BYPASSED DETECTORS SYSTEM STATUS SETTINGS DISPLAY SETTING MAINTENANCE MODE Allo...

Page 15: ...ter the exit delay has expired then the control panel will unset again Unsuccessful setting is indicated by a system indicator ashing yellow reported to the ARC and indicated by an external siren appl...

Page 16: ...tors will not trigger the alarm when somebody moves inside the section 1 When you enter the building triggering a detector with a De layed zone reaction the system starts indicating an entrance delay...

Page 17: ...he status indicator and the function button rapidly ashing red You need to authorize yourself using the keypad in order to terminate the alarm The section remains set a rapidly ashing red function but...

Page 18: ...a device is triggered It is necessary to con rm setting by pressing the lock button again A set section will be con rmed by a red LED light The keyfob buttons can be blocked to prevent accidental pres...

Page 19: ...commands can control individual sections and programmable outputs just like keypad segment buttons The form of text message to operate the system is CODE_COMMAND The actual commands are prede ned SET...

Page 20: ...G is shown by a PG number in a rectangle fi lled with black colour Press ESC to exit the menu 2 2 6 4 REMOTE CONTROL By pressing an assigned button of a remote control Bi directional remote controls c...

Page 21: ...Link software by clicking on the detector in the Settings Diagnostics Disabled column A blocked detector is marked with a yellow circle until it is turned back on using the same procedure A device can...

Page 22: ...change must be saved by selecting Save when the system prompts with Save Settings The system administrator and the service technician can add modify or delete a user phone number or change a user name...

Page 23: ...supply 110 230 V 50 60 Hz max 0 28 A with fuse F1 6 A 250 V Protection class II 110 230 V 50 60 Hz max 0 85 A with fuse F1 6 A 250 V Protection class II Back up battery 12 V 2 6 Ah lead gel 12 V 7 to...

Page 24: ...g date and time Power supply unit Type A according to EN 50131 6 T 031 note In case of a main power failure is the system backed up for 24 hours and at the same time is a failure report sent to the AR...

Page 25: ...SCAN ME...

Page 26: ...www jablotron com M ENJA100 USER...

Reviews: