E l e c t r i c a l I n s t a l l a t i o n
- 20 -
Model 10 - 85
Model 140/300
The connectors of the actuator are DIN connectors. Make sure that the connection cables have the
correct diameter and the gaskets are installed correctly in the connector gland, otherwise the
protection class can not be guaranteed and humidity enters the actuator. The connectors are
secured to the actuator with a screw.
Cable diameter:
model
min.
Ø
max.
Ø
min.
Ø
max.
Ø
10 - 85
5mm
5mm
8mm
10,5mm
140 - 300
-
-
8mm
10,5mm
small plug
large plug
Type C
industrial standard
Type A
DIN EN 175301-803A
Standard actuators are single phase to connect. An external fuse must be provided. Do not
connect consumers in parallel to the actuator.
Connectors
Electrical Installation
1 Seal
2 Spindle Clamp
3 C
4 Housing
5 Seal
6 Washer
7 Cable Gland
8 Washer
9 Locating Screw
10 Seal
able Clamp
Make sure that the screw will not overwound!