75
burner and making
soot.
6B. Air restrictor is not open
enough.
6C. Vent is blocked or defective.
adjust as described in section
4.1.
6B: Adjust gas intake and exhaust
properly as described in section
4.1.
6C: Contact a certified technician to
have your vent ducts inspected.
7. When I turn on my
fireplace, there are long
blue flames coming off
the burner and the
fireplaces stops
working after a minute.
7A. Not enough air intake.
7B. Gas exhaust panel is not open
enough.
7C. Vent is blocked or defective.
7A: Start by checking the air/gas
premix adjustment screw and
adjust as described in section
4.1.
7B. Adjust gas intake and exhaust
properly as described in section
4.1.
7C: Contact a certified technician to
have your vent ducts inspected.
8. I smell gas.
8B. Refer to the front page of this
manual immediately and follow
instructions
9. My remote control
cannot turn off the
fireplace.
9A. Batteries in the remote control
are dead.
9B. You are too far from the
fireplace.
9C. A component of the
SmartCase
®
is
defective.
9A. Change the batteries in the
remote control.
9B. Move closer to the fireplace.
9C. Close the manual valve
upstream from the fireplace and
call your J. A. ROBY retailer.
10. When I turn my
fireplace off, the pilot
light remains lit.
10A. Your fireplace is in CPI mode.
10A. Refer to section 4.2.2 to set
the remote control in IPI mode.
11. A lot of soot is
accumulating on the
inner walls of the
fireplace.
11A. The exhaust panel is not open
enough and causes poor
combustion.
11B. The vent is blocked
11A. Refer to section 4.1 to adjust
the gas exhaust panel in a
more open position.
11B: Contact a certified technician
to have your vent system
inspected.
12. The flame intensity
varies.
12A Your fireplace is in thermostat
mode
12A. Refer to section 4.2.2 to
deactivated thermostat mode
Summary of Contents for loo RGR-25