3.1.6. SHELF SIZE
A shelf may be installed above the fireplace as long as it complies with the authorized dimensions. Non-
compliance could result in a fire.
3.2. VENT INSTALLATION
3.2.1. INSTALLATION PRECAUTIONS
• The installer must make sure to read and understand section 1.2.1 of this manual regarding
installation instructions.
• This appliance must be installed in combination with a ventilation system approved by J. A. ROBY.
Consult local building codes before starting the installation.
• The installer must use a vent configuration adapted to the installation.
Before installing the vent, the installer must read this fireplace
’s and the vent kit’s manuals.
• Vents should only be installed by a qualified installer/technician. This person must comply with the
following safety rules:
• Wear gloves and safety glasses for his own protection.
• Be very careful when working on a roof or with ladders.
• Find where electrical wires are located in walls and ceiling.
The following actions will void your vent system
’s warranty:
• Installation of any damaged vent system component.
• Unauthorized modification of the vent system.
• Installation that differs in any way from the one specified in section 3.2, INSTALLATION OF THE
VENT.
• Installation of any component not manufactured or approved by J. A. ROBY.
SHELF SIZE (IN.)
Distance from the
top of the fireplace
Authorized shelf
depth
0
2
1
3
2
4
3
5
4
6
5
7
6
8
7
9
Figure 3.1.5.b
Figure 3.1.5.a