58
6.6. VERIFICATION OF GAS LINE TIGHTNESS
Fill a spray bottle (figure 6.6) with soapy water (5% soap, 95% water).
Spray liberally over all screwed gas line connections (from the tank to the
fireplace).
If no bubbles appear it means the assembly is tight.
If there are bubbles, it means there is a gas leak. If this occurs, immediately
refer to section 1.2.1 and follow instructions.
6.7. OPEN OR CLOSE MANUAL VALVE
To open or close manual valve, pull the little access panel at the base of the stove and turn the knob to
the require position as shown on Figure 6.7
Figure 6.6
Figure 6.7
WARNING
Never use an open flame to check for gas leaks.
Summary of Contents for loo RGR-25