12
• Gas accumulation may ignite when purging the line.
• Purge must be performed by a qualified technician.
• When purging gas lines, make sure there are no ignition sources such as sparks or open flames in the
same room as the fireplace.
• The adjustment of the valve is set at the factory. Do not modify.
• Do not connect 110 V wires to the fireplace’s valve.
• Never let any fuel or other volatile liquids (gasoline or alcohol) near your fireplace when it is operating.
• Do not obstruct fuel or air inlets in any way.
• Improper wiring will override the safety interlock system, which could cause an explosion.
• If you smell gas, carry out the steps indicated in paragraph 1.1 immediately.
• This unit is equipped with injectors sized specifically for use with natural gas (or propane gas). Do not
attempt to change the injectors in any way; this will cause abnormal operation of the unit and may cause
a fire.
1.2.4. MAINTENANCE
• You should have this fireplace inspected by a qualified technician every year. Make a habit of having
your gas fireplaces inspected once a year.
• If the glass door have to be replaced, we suggest to call a qualified technician to do it.
• Turn off the fireplace and let it cool before servicing or repairing it. Installation or repair of the fireplace
must be performed only by a qualified technician. Have the burner inspected every year.
• Always make sure the unit is working properly after every maintenance operation.
• Always keep the control boxes and burner clean. Turn off the gas supply before cleaning the fireplace.
• This unit is equipped to run on natural or propane gas. Conversion must be made by a qualified
technician.
• Have the exhaust system and the fireplace inspected by a qualified technician every year before the
heating season begins.
• Use a gentle cleaner on the windows. Do not use abrasive products; they will damage the surface of the
glass.
J. A. ROBY assumes no liability and makes no warranties in following cases:
A bad installation,
A usage with a damaged component,
A vent system installation that does not meet J. A. ROBY
’s instructions,
Crushed glass was not placed properly on the burner,
A usage of any component not approved by J. A. ROBY.
WARNING:
It is important to handle all appliance components (doors,
SmartCase
®
, burner, etc.) with care during maintenance.
THE INSTALLER MUST READ THIS MANUAL CAREFULLY BEFORE INSTALLING OR USING THIS
APPLIANCE. PLEASE REFER TO LOCAL CODES, WHERE APPLICABLE.
Summary of Contents for loo RGR-25
Page 18: ...18 2 3 FIREPLACE DIMENSIONS 2 3 1 LOO RGR 25 INSERT 2 3 2 MISTRAL RGP 25 PENINSULA...
Page 19: ...19 2 3 3 AUSTER RGCG 25 LEFT CORNER 2 3 4 MOUSSON RGCD 25 RIGHT CORNER...
Page 20: ...20 2 3 5 SIROCCO RGB 25 PANORAMIC 2 3 6 PAMPERO RGC 25 CENTRAL...
Page 21: ...21 2 3 7 SUROIT RGV 25 SEE THRU...