Impeller Assembly -
The rotating assembly is made
up of the stainless steel impeller shaft, stainless steel
flag indicator, and stainless steel impeller blades. The
impeller assembly can be removed by pulling on the
top plate.
CAUTION: KEEP BODY APPENDAGES OR
LOOSE CLOTHING AWAY FROM THE IMPELLER
ASSEMBLY WHILE THE MACHINE IS OPERATING!
IF MAINTENANCE IS REQUIRED, BE SURE TO
TURN THE SOLARBEE OFF FIRST!
The flag indicator is fixed to the shaft and used as a
visual indicator of the impeller shaft's rotational speed.
The impeller blades are welded to a hub that is
fastened to the impeller shaft. The impeller is designed
to gently pump water from below and can handle up to
7.6cm (3-inch) spherical solids.
The impeller bushing is a smooth collar that the
impeller shaft tip fits into. The impeller bushing aligns
and centers the impeller shaft within the machine
.
Turn SolarBee Off Before Performing Maintenance
Flag Indicator
Impeller Blades
Impeller Hub
SB500PWc Impeller Assembly
Top Plate
Impeller
Bushing
U-Joint
Shaft
Coupling
© 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | [email protected]