INSTALLATION MANUAL (

HiE-SxxxSG/SI

, IEC) 

Issued on Sep. 17

th

, 2019

 

1.  General Information

 

·

 

This Installation manual contains information regarding the installation and the safe handling  method 
of the photovoltaic module (hereafter referred to as “

module

”) supplied by Hyundai Energy Solutions 

Co., Ltd. (hereafter referred to as “

HES

”). 

·

 

HiE-SxxxSG: 340 pieces, 325-350W, 1500V 

HiE-SxxxSI: 408 pieces, 395-420W, 1500V 

·

 

System  users  and  installers  should  read  and  understand  this  manual  before  handling,  installing  the 

module. Please contact Customer Support department or our local representatives for more detailed 

information. 

·

 

Before  installing  solar  photovoltaic  systems,  mechanical  and  electrical  requirements  for  the  total 

system should be checked as well. Keep this manual in a safe place for future reference. 

·

 

The installer should consider every safety precautions specified in this manual and local codes when 

installing a module.   

·

 

HES modules are tested and certified for installation worldwide. Different regions may have different 
regulations for solar PV installations. In this manual, hereafter “IEC only” is used to refer to regions 
where  IEC  standard  applies,  e.g.  Europ

e,  Middle  East,  most  of  Asia  Pacific  countries;  “UL  only”  is 

used to refer to regions where UL standard applies, e.g. United States, Canada; all other references 

are global. 

 

1.1 

   

·

 

Installing  solar  photovoltaic  systems  requires  specialized  skills  and  knowledge.  Thus,  before 

installation,  wiring,  and  operation  of  photovoltaic  modules,  system  users  and  installer  should 

understand and conform to this manual. 

·

 

Installation and wiring should only be performed and supervised by qualified persons. 

·

 

Each  module  has  a  junction  box  for  permanent  cable  connection.  HES  can  provide  customers  with 

fitted  cables  for  easy  installation.  Installers  should  secure  the  safe  installation  status  including  all 

electrical hazards. 

 

1.2                     

·

 

Installers should secure the installation status, without limitation, including the risk of electric shock. 

·

 

Backsheet of PV module should be kept safe from any damage or scratch to prevent mechanical or 

electric shock. 

·

 

Do not disassemble or remove any part of a PV module. Such actions may cause electric shock, fire 

or damage. 

·

 

Keep  safety  regulations  for  all  components  used  in  the  system,  including  wiring  and  cables, 
connectors, charging regulators, inverters, storage batteries and rechargeable batteries, etc. 

 
 
 

Summary of Contents for HiE-S SG Series

Page 1: ... Different regions may have different regulations for solar PV installations In this manual hereafter IEC only is used to refer to regions where IEC standard applies e g Europe Middle East most of Asia Pacific countries UL only is used to refer to regions where UL standard applies e g United States Canada all other references are global 1 1 Installing solar photovoltaic systems requires specialize...

Page 2: ... connectors or junction boxes in order to prevent electric shock and injury Be sure the circuit breaker is off if it s applicable Always use appropriate safety equipment Insulated tools insulating gloves etc Do not re arrange bypass diodes where it may cause electric shock and injury Do not disconnect the cable when the load to module is engaged Check applied Class for module after installing the ...

Page 3: ...s and modules which might cause module damage and cell crack during transportation Store the modules safely in a dry and cool environment Do not stack or move more than two packages of modules which are stacked vertically Workers are recommended to keep some distance from the package when one worker cuts banding tapes Don t lift the package after removing banding tapes After unpacking please visua...

Page 4: ...educe pressure loads and improve module ventilation The minimum distance between a module frame and a sidewall of clamp for linear thermal expansion of the module frame supports should be 1 5 mm in order to reduce pressure loads All the junctions on the conductive connection must be fixed Metal containing iron in the conductive connection should be made with stainless steel or be treated against c...

Page 5: ...lled in sulfurous area near sulfurous volcano and sulfurous spring If PV modules are installed near factory or plant area they can be polluted by fumes and the pollution may not be cleaned Thus the installer should consider and check the installation area and the distance from factory or plant area If PV modules are installed in damp environments the installer should check the installation area to...

Page 6: ...nam si Gyeonggi do 13591 Korea Factory 313 Soi ro Soi myeon Eumseong gun Chungcheongbuk do 369 872 Korea Module M8 Screw Flat washer Spring washer M8 Nut The Support rail Picture 1 Installation Method using stainless steel bolt nut The support rail Clamp B Clamp A Picture 2 Mounting Hardware Clamp ...

Page 7: ... a module arrangement with combined electrical connection The array must be insulated to resist against the possible maximum open circuit voltage Also solar irradiation proof copper wires must be used for array wiring Installers must check the local electrical specifications In order to prevent cable drooping installers should fix cable using wire or duct 5 4 Earth Ground Wiring To prevent electri...

Page 8: ...On the junction box the polarity is clearly marked 1 Protection Degree IP67 2 Temperature Range 40 C 90 C 3 Wire Size 4 0mm 2 AWG 12 4 The cable must not be bent or crushed on the direct exit of the cable screw joint A minimum bending radius 43mm must be maintained The cable must be routed in a way that tensile stress on the conductor or connections is prevented Picture 4 Picture 4 Cable Routing 5...

Page 9: ...modules are equipped with bypass diodes If installer wishes to change into other diodes the installer should inform an authorized engineer of HES Object Manufacturer Type Technical Data Junction Box Zhejiang Renhe Photovoltaic Technology Co Ltd GF26xy Max Voltage 1500 V DC Rated current 15 A RTI 110 Bypass diodes PST6020 Tj max 200 C If 20A PST4530 T Tj max 200 C If 20A Cable H1Z2Z2 K 1 x4 0 mm 2 ...

Page 10: ... module glass surface clean For AR coating HES modules utilize special materials to increase energy harvest Always use clean gloves when handling the module never touch the glass with bare hands If dirt build up becomes excessive clean the glass surface with room temperature water and soft materials without potential risks of scratch Do not use water with high pressure for cleaning Do not use hars...

Page 11: ...t have any responsibility and liability for clause as below Loss damage injury or expense resulting from improper installation handling or use The installation techniques handling and use of this product are beyond company control Infringement of any third party s patent or right that is caused by using HES modules Loss damage injury or expense resulting from any factor that is unsuspected the mod...

Page 12: ...d Safety factor 1 5 Method SG Overlap of Clamp with Al frame 8 10mm SI Overlap of Clamp with Al frame 9 11mm Bolting 4 Bolts 1600 1600 Pa 8 Bolts 3600 1600 Pa Clamping Clamping area Min Clamp Width 50mm on Long Bar A 330 50mm 3600 1600Pa or 2400 2400 Pa A 330 50mm Design load 2400 2400Pa A 330 50mm B 971 50mm Design load 3600 1600Pa Note 1 Certified by TUV NORD 2 The Mounting method has been quali...

Page 13: ...utput tolerance W 5 0 Maximum system voltage Vdc IEC 1 500 Cell quantity in series pcs 340 Bypass diodes pcs 2 Cell Type Mono crystalline Silicon Cell Application Safety Class Class A Class II Fire rating Class C IEC Electrical Characteristics HiE SxxxSI Item HiE SxxxSI xxx Maximum Power Value Maximum Power at STC Pmax W 420 415 410 405 400 395 Voltage at Pmax Vmpp V 37 7 37 6 37 5 37 4 37 3 37 2 ...