3.  Installation Environment 

3.1   General 

·

 

Before installing and operating HES PV system, installer and operator should follow the requirements 

specified in this manual. 

·

 

Do not drill additional  holes in the frame of the modules. This  additional hole  will  void the  warranty. 

Refer to the mounting profile in Picture 1. 

 

·

 

Secure the module using mounting holes provided and stainless corrosion resistant material. Locking 

washers should be used for long-term security. 

·

 

Appropriate  materials  should  be  used  for  mounting  structure  in  order  to  prevent  the  module  frame, 

mounting structure from corrosion. 

·

 

When installing the system, it is necessary to avoid any shade caused by buildings or trees nearby. 

·

 

For more information about the installation, please contact HES or local representatives for more 
detailed information. 

 

3.2   Notes on Installation   

·

 

Space between PV module frames and installation objects is necessary for cooling air circulation. Do 

not seal this space. Minimum 4 inch (10.14 cm) of standoff height is necessary.

   

·

 

The minimum distance between two fixed modules for linear thermal expansion of the module frame 

supports  should  be  10  mm.  Nevertheless,  the  recommended  distance  between  two  modules  is  30 

mm to allow wind circulation, in order to reduce pressure loads and improve module ventilation. 

·

 

The minimum distance between a module frame and a sidewall of clamp for linear thermal expansion 

of the module frame supports should be 1.5 mm, in order to reduce pressure loads. 

·

 

All the junctions on the conductive connection must be fixed.

 

Metal containing iron in the conductive 

connection should be made with stainless steel or be treated against corrosion by anodizing, spray-

painting, or galvanization to prevent rusting and corrosion. 

·

 

Modules  that feature antireflective coated  glass are prone  to visible finger print marks if touched  on 

the  front  glass  surface.  HES  recommends  handing  modules  with  gloves  or  limiting  touching  of  the 

front  surface.  Any  finger  print  marks  resulting  from  installation  will  naturally  disappear  over  time  or 

can be reduced by following the washing guidelines in Section 6.2. 

·

 

Do  not  install  PV  modules  horizontally.  Horizontal  installation  can  cause  performance  drop  of  PV 

modules. HES recommends mounting modules at a 12.5° tilt or greater. 

 

3.3   Installation Site 

PV modules  will be operated under General Operation Condition (GOC). Do not install PV module at 

site beyond General Operation Conditions or under specific condition. 

 

1)  General Site Conditions 

The site condition for the sea level and wind load should be matched the following requirements. 

(1) Sea level of site : Below 1,000 m (3,280 ft) 

(2) Maximum Instantaneous wind Speed (design load, safety factor = 1.5) 

·

 

Below 2,400Pa or 3,600Pa on the front module surface 

·

 

Below 1,600Pa or 2,400Pa on the back module surface 

 

If  the  wind  strength  is  not  over  than  2,400Pa  (2,400  N/m

2

,  245  kg/m

2

,

 

50  lb/ft

2

),  the  installation 

Summary of Contents for HiE-S SG Series

Page 1: ... Different regions may have different regulations for solar PV installations In this manual hereafter IEC only is used to refer to regions where IEC standard applies e g Europe Middle East most of Asia Pacific countries UL only is used to refer to regions where UL standard applies e g United States Canada all other references are global 1 1 Installing solar photovoltaic systems requires specialize...

Page 2: ... connectors or junction boxes in order to prevent electric shock and injury Be sure the circuit breaker is off if it s applicable Always use appropriate safety equipment Insulated tools insulating gloves etc Do not re arrange bypass diodes where it may cause electric shock and injury Do not disconnect the cable when the load to module is engaged Check applied Class for module after installing the ...

Page 3: ...s and modules which might cause module damage and cell crack during transportation Store the modules safely in a dry and cool environment Do not stack or move more than two packages of modules which are stacked vertically Workers are recommended to keep some distance from the package when one worker cuts banding tapes Don t lift the package after removing banding tapes After unpacking please visua...

Page 4: ...educe pressure loads and improve module ventilation The minimum distance between a module frame and a sidewall of clamp for linear thermal expansion of the module frame supports should be 1 5 mm in order to reduce pressure loads All the junctions on the conductive connection must be fixed Metal containing iron in the conductive connection should be made with stainless steel or be treated against c...

Page 5: ...lled in sulfurous area near sulfurous volcano and sulfurous spring If PV modules are installed near factory or plant area they can be polluted by fumes and the pollution may not be cleaned Thus the installer should consider and check the installation area and the distance from factory or plant area If PV modules are installed in damp environments the installer should check the installation area to...

Page 6: ...nam si Gyeonggi do 13591 Korea Factory 313 Soi ro Soi myeon Eumseong gun Chungcheongbuk do 369 872 Korea Module M8 Screw Flat washer Spring washer M8 Nut The Support rail Picture 1 Installation Method using stainless steel bolt nut The support rail Clamp B Clamp A Picture 2 Mounting Hardware Clamp ...

Page 7: ... a module arrangement with combined electrical connection The array must be insulated to resist against the possible maximum open circuit voltage Also solar irradiation proof copper wires must be used for array wiring Installers must check the local electrical specifications In order to prevent cable drooping installers should fix cable using wire or duct 5 4 Earth Ground Wiring To prevent electri...

Page 8: ...On the junction box the polarity is clearly marked 1 Protection Degree IP67 2 Temperature Range 40 C 90 C 3 Wire Size 4 0mm 2 AWG 12 4 The cable must not be bent or crushed on the direct exit of the cable screw joint A minimum bending radius 43mm must be maintained The cable must be routed in a way that tensile stress on the conductor or connections is prevented Picture 4 Picture 4 Cable Routing 5...

Page 9: ...modules are equipped with bypass diodes If installer wishes to change into other diodes the installer should inform an authorized engineer of HES Object Manufacturer Type Technical Data Junction Box Zhejiang Renhe Photovoltaic Technology Co Ltd GF26xy Max Voltage 1500 V DC Rated current 15 A RTI 110 Bypass diodes PST6020 Tj max 200 C If 20A PST4530 T Tj max 200 C If 20A Cable H1Z2Z2 K 1 x4 0 mm 2 ...

Page 10: ... module glass surface clean For AR coating HES modules utilize special materials to increase energy harvest Always use clean gloves when handling the module never touch the glass with bare hands If dirt build up becomes excessive clean the glass surface with room temperature water and soft materials without potential risks of scratch Do not use water with high pressure for cleaning Do not use hars...

Page 11: ...t have any responsibility and liability for clause as below Loss damage injury or expense resulting from improper installation handling or use The installation techniques handling and use of this product are beyond company control Infringement of any third party s patent or right that is caused by using HES modules Loss damage injury or expense resulting from any factor that is unsuspected the mod...

Page 12: ...d Safety factor 1 5 Method SG Overlap of Clamp with Al frame 8 10mm SI Overlap of Clamp with Al frame 9 11mm Bolting 4 Bolts 1600 1600 Pa 8 Bolts 3600 1600 Pa Clamping Clamping area Min Clamp Width 50mm on Long Bar A 330 50mm 3600 1600Pa or 2400 2400 Pa A 330 50mm Design load 2400 2400Pa A 330 50mm B 971 50mm Design load 3600 1600Pa Note 1 Certified by TUV NORD 2 The Mounting method has been quali...

Page 13: ...utput tolerance W 5 0 Maximum system voltage Vdc IEC 1 500 Cell quantity in series pcs 340 Bypass diodes pcs 2 Cell Type Mono crystalline Silicon Cell Application Safety Class Class A Class II Fire rating Class C IEC Electrical Characteristics HiE SxxxSI Item HiE SxxxSI xxx Maximum Power Value Maximum Power at STC Pmax W 420 415 410 405 400 395 Voltage at Pmax Vmpp V 37 7 37 6 37 5 37 4 37 3 37 2 ...

Reviews: