background image

 

                                                                                                     

www.hyundai-es.co.kr

 

 

 

Page 9 of 13 

 

 

Sales Office 

4th Fl., First Tower, 
55, Bundang-ro, Bundang-gu, 
Seongnam-si, Gyeonggi-do, 
13591 Korea 

Factory 

 

313, Soi-ro, Soi-myeon, Eumseong-gun, 
Chungcheongbuk-do 369-872, Korea 

 

 

 

 

 

 

 

 

 

Picture 5. Connect connectors 

 

9)  If the connectors need to be disconnected, installer should use the exclusive tool to disconnect them 

after safety measure such as cut-off of connection band. 

10)   Connected cables and connectors should be fixed.

 

11)   Action against contamination or corrosion should be enacted on disconnected connectors.

 

 

5.7   Conduit 

For  conduit  application,  it  is  necessary  to  follow  the  regulation  for  outdoor  installation  of  conduit.  All 

fixing parts should be protected from any damage and moisture. 

 

5.8   Diode 

When there is partial shade on a PV module, reverse-voltage can 

occur

 inside PV module. In order to 

protect this phenomenon, the diodes are normally installed in  the Junction Box. HES PV modules are 

equipped with bypass diodes. If installer wishes to change into other diodes, the installer should inform 

an authorized engineer of HES.

 

 

Object 

Manufacturer 

Type 

Technical Data 

Junction Box 

Zhejiang Renhe 

Photovoltaic Technology 

Co., Ltd. 

GF26xy 

Max. Voltage=1500 V (DC) 

Rated current = 15 A RTI = 110

 

Bypass diodes 

PST6020 

Tj max = 200°C    If = 20A 

PST4530/T 

Tj max = 200°C    If = 20A 

Cable 

H1Z2Z2-K 1 x4.0 mm

2

 

Rated voltage = 1500VDC 

Connectors 

05-8 

Rated voltage = 1500VDC 

Rated current = 30A 

Staubli 

PV-KST4-EVO 2/xy_UR 
PV-KBT4-EVO 2/xy_UR 

Rated Voltage = 1500VDC 

Rated Current = 45A (4.0mm

2

 

Object 

Manufacturer 

Type 

Technical Data 

Junction Box 

Tongwei solar(Hefei) Co., 

Ltd. 

PVJB-TW-S/001 

Max. Voltage=1500 V (DC) 

Rated current = 15 A RTI = 110

 

Bypass diodes 

Changzhou 

Starsea Electronics 

PST6020 

Tj max = 200°C    If = 20A 

Yangzhou Yangjie 

Electronic Technology 

GF3045MG 

Tj max = 200°C    If = 30A 

Cable 

Zhejiang Renhe 

Photovoltaic Technology 

Co., Ltd. 

H1Z2Z2-K 1 x4.0 mm

2

 

Rated voltage = 1500VDC 

Connectors 

05-8 

Rated voltage = 1500VDC 

Rated current = 30A 

Staubli 

PV-KST4-EVO 2/xy_UR 
PV-KBT4-EVO 2/xy_UR 

Rated Voltage = 1500VDC 

Rated Current = 45A (4.0mm

2

Summary of Contents for HiE-S SG Series

Page 1: ... Different regions may have different regulations for solar PV installations In this manual hereafter IEC only is used to refer to regions where IEC standard applies e g Europe Middle East most of Asia Pacific countries UL only is used to refer to regions where UL standard applies e g United States Canada all other references are global 1 1 Installing solar photovoltaic systems requires specialize...

Page 2: ... connectors or junction boxes in order to prevent electric shock and injury Be sure the circuit breaker is off if it s applicable Always use appropriate safety equipment Insulated tools insulating gloves etc Do not re arrange bypass diodes where it may cause electric shock and injury Do not disconnect the cable when the load to module is engaged Check applied Class for module after installing the ...

Page 3: ...s and modules which might cause module damage and cell crack during transportation Store the modules safely in a dry and cool environment Do not stack or move more than two packages of modules which are stacked vertically Workers are recommended to keep some distance from the package when one worker cuts banding tapes Don t lift the package after removing banding tapes After unpacking please visua...

Page 4: ...educe pressure loads and improve module ventilation The minimum distance between a module frame and a sidewall of clamp for linear thermal expansion of the module frame supports should be 1 5 mm in order to reduce pressure loads All the junctions on the conductive connection must be fixed Metal containing iron in the conductive connection should be made with stainless steel or be treated against c...

Page 5: ...lled in sulfurous area near sulfurous volcano and sulfurous spring If PV modules are installed near factory or plant area they can be polluted by fumes and the pollution may not be cleaned Thus the installer should consider and check the installation area and the distance from factory or plant area If PV modules are installed in damp environments the installer should check the installation area to...

Page 6: ...nam si Gyeonggi do 13591 Korea Factory 313 Soi ro Soi myeon Eumseong gun Chungcheongbuk do 369 872 Korea Module M8 Screw Flat washer Spring washer M8 Nut The Support rail Picture 1 Installation Method using stainless steel bolt nut The support rail Clamp B Clamp A Picture 2 Mounting Hardware Clamp ...

Page 7: ... a module arrangement with combined electrical connection The array must be insulated to resist against the possible maximum open circuit voltage Also solar irradiation proof copper wires must be used for array wiring Installers must check the local electrical specifications In order to prevent cable drooping installers should fix cable using wire or duct 5 4 Earth Ground Wiring To prevent electri...

Page 8: ...On the junction box the polarity is clearly marked 1 Protection Degree IP67 2 Temperature Range 40 C 90 C 3 Wire Size 4 0mm 2 AWG 12 4 The cable must not be bent or crushed on the direct exit of the cable screw joint A minimum bending radius 43mm must be maintained The cable must be routed in a way that tensile stress on the conductor or connections is prevented Picture 4 Picture 4 Cable Routing 5...

Page 9: ...modules are equipped with bypass diodes If installer wishes to change into other diodes the installer should inform an authorized engineer of HES Object Manufacturer Type Technical Data Junction Box Zhejiang Renhe Photovoltaic Technology Co Ltd GF26xy Max Voltage 1500 V DC Rated current 15 A RTI 110 Bypass diodes PST6020 Tj max 200 C If 20A PST4530 T Tj max 200 C If 20A Cable H1Z2Z2 K 1 x4 0 mm 2 ...

Page 10: ... module glass surface clean For AR coating HES modules utilize special materials to increase energy harvest Always use clean gloves when handling the module never touch the glass with bare hands If dirt build up becomes excessive clean the glass surface with room temperature water and soft materials without potential risks of scratch Do not use water with high pressure for cleaning Do not use hars...

Page 11: ...t have any responsibility and liability for clause as below Loss damage injury or expense resulting from improper installation handling or use The installation techniques handling and use of this product are beyond company control Infringement of any third party s patent or right that is caused by using HES modules Loss damage injury or expense resulting from any factor that is unsuspected the mod...

Page 12: ...d Safety factor 1 5 Method SG Overlap of Clamp with Al frame 8 10mm SI Overlap of Clamp with Al frame 9 11mm Bolting 4 Bolts 1600 1600 Pa 8 Bolts 3600 1600 Pa Clamping Clamping area Min Clamp Width 50mm on Long Bar A 330 50mm 3600 1600Pa or 2400 2400 Pa A 330 50mm Design load 2400 2400Pa A 330 50mm B 971 50mm Design load 3600 1600Pa Note 1 Certified by TUV NORD 2 The Mounting method has been quali...

Page 13: ...utput tolerance W 5 0 Maximum system voltage Vdc IEC 1 500 Cell quantity in series pcs 340 Bypass diodes pcs 2 Cell Type Mono crystalline Silicon Cell Application Safety Class Class A Class II Fire rating Class C IEC Electrical Characteristics HiE SxxxSI Item HiE SxxxSI xxx Maximum Power Value Maximum Power at STC Pmax W 420 415 410 405 400 395 Voltage at Pmax Vmpp V 37 7 37 6 37 5 37 4 37 3 37 2 ...