If you find that the SolarBee has quit operating, the
following checks can be performed:
Connection Check -
1) Locate the digital controller and be sure that
each PV module cord is properly connected.
2) Check that the battery is properly connected.
3) Follow each cord from the electronic controller
to its originating component and be sure it is not
damaged.
Visual Digital Controller Check
-
The
SolarBee contains an LED (Light Emitting Diode)
blink sequence that indicates the machine
operation status. The blinking LEDs are found on
the Brain-board located inside the digital controller.
A solid green LED is also located on the Zahn
board. To observe the LEDs,
1) Open the door of the digital controller and locate
the laminated LED label on the inside of the door.
2) Using the LED label, locate the Brain-board and
the Zahn board. Observe and record the blinking
LEDs (color and # of blinks in succession) and solid
green LED (off or on).
3) Using the LED label, match your blink
observations to the corresponding indication. Use
the information on the next two pages to proceed.
DC Voltage Check -
If a DC voltmeter is available, the battery voltage
can be measured off of the brainboard at the 3-pin
connection (white, black, and orange leads).
1) Using the voltmeter positive lead on the white
screw terminal and voltmeter negative lead on the
black screw terminal, the voltage can be measured.
2) Record the measurement.
SCADA Information
-
SolarBee operation
status information can be transmitted from the
machine to a nearby monitoring station by using
one of SolarBee's various SCADA kits. Contact
Ixom Watercare, Inc. Customer Service for more
information.
12 VDC+
12 VDC-
SolarBee Installation / Service Crew
Ixom Watercare, Inc. is committed to serving
our customers. Feel free to contact a SolarBee
Customer Service Representative if you experience
any problems with your SolarBee. At SolarBee, we
will get you technical support, parts, or a service
visit to make sure that your SolarBee is back online
in short time. (866) 437-8076 or customerservice@
ixom.com
© 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | [email protected]
Troubleshooting
Troubleshooting
SB Series
2053_10238_20210309