68
Items to be checked
Countermeasures
References
Items to be checked
Countermeasures
References
11. Troubleshooting
The transfer direction is
different from the setting
Has the MABS main unit been
installed in the correct direction?
Align the installation direction
of the MABS main unit (turn the
row of less transfer balls to the
upstream side).
11. Troubleshooting
Symptoms
When loading/discharging,
totes get stuck, or cannot
be transferred
7. Installation/
Wiring
(⇒
P.31
)
7. Installation/
Wiring
(⇒
P.31
)
7. Installation/
Wiring
(⇒
P.34
)
Have M1: Transfer motor and
M2: Swing motor been
connected correctly?
Shut down the controller´s power,
and connect motors correctly.
Have proximity sensor for origin
position type in the MABS main
unit and controller type (NPN
input / PNP input) been matched?
Match the proximity sensor type
in the MABS main unit and
controller type (NPN input / PNP
input).
Align transfer surface level of the
infeed/discharge conveyor and
MABS unit.
Have the transfer balls become
worn?
Replace the transfer ball
element set.
Is the swing angle when
diverting correct?
Adjust the swing angle.
8. IB-E06F-M1
settings
(⇒
P.48
)
10. Maintenance
and inspection
(⇒
P.63
)
5. Product check
(⇒
P.20
)
6. Structures
(⇒
P.22
)
Is transfer surface level of
infeed/discharge conveyor and
MABS unit same?
※
Check the model of MABS main unit
and controllers.
MABS technical document
Safety precautions
Advanced preparation
Product check
Structures
Installation/Wiring
Control/Operation
Maintenance/Inspection
Troubleshooting
Appendix
IB-E06F-M1 settings
Original notice - U1.1