47
Property setting
Click “Write”.
4
Write
■
Perform the above settings for both master and synchronized units.
Motor settings
Perform the motor settings.
1
3
7
4
5
※
Indicates the transfer speed. Enter the value within the range of between 30 and 90 m/min.
6
■
Other settings will be automatically specified.
Set the motor type to “Other”.
Select “MABS2_E06_V
×××
” for the logic.
Select the motor tab.
Set the roller diameter to “64.0” for Motor A, and “87.0” for Motor B.
Set the gear reduction to “5” for Motor A, and “53.59” for Motor B.
Set the speed 1 to 4 to “90.0” for Motor A, and “17.0” for Motor B.
Set the motor current limitation to “7.00A” for both Motor A and Motor B.
※
1
2
3
4
5
6
7
Set the motor A for rotation direction switching to “CCW”.
8
Click “Write”.
9
8. IB-E06F-M1 settings
MABS technical document
Safety precautions
Advanced preparation
Product check
Structures
Installation/Wiring
Control/Operation
Maintenance/Inspection
Troubleshooting
Appendix
IB-E06F-M1 settings
Setting the IP address / Checking connection
↓
Creating the project file
↓
Registering IB-E06F-M1 to be used
↓
Registering comments
↓
Network settings
Complete
↓
Motor settings
↓
Swing angle settings
↓
Click
Click
Click
9
8
2
MABS2_E06_V
×××
MABS2_E06_V
×××