20
5. Product check
・
Depending on the sensor input signal type, controllers with the NPN (N) or PNP (P)
signal input are attached.
・
One set of the following items is attached per one unit.
Checking accessories
Check that all the following items are included.
Cross-recessed
pan head screw
M4×10
Hex. nut
M4
Spring washer
M4
Controller IB-E06F-N-UL-M1
×1
Power connector
wago231-302/026-000
Remote input connector
wago734-204
Remote output connector
wago734-206
Sensor connector
wago733-104
Controller/Connectors
Extension cable
For MABS2
−
K90
− □
A
□−
C2
−
P01
For MABS2
−
K90
−
−
C2
−
P01
< For swing/transfer >
×1
×1
×1
×2
×2
×2
×2
Cross-recessed
pan head screw
M4×10
Hex. nut
M4
Spring washer
M4
Power connector
wago231-302/026-000
Remote input connector
wago734-204
Remote output connector
wago734-206
Sensor connector
wago733-104
×1
×1
×1
×2
×2
×2
×2
Controller IB-E06F-P-UL-M1
×1
Extension cable
×2
< For swing/transfer >
Checking the model
Unpack the product, and check that the product model is what you ordered.
Checking appearance
①
Check that the main unit is free from any abnormalities, such as traces of scratches,
dents, dirt, and/or corrosion (rust).
②
Check that there is no omission and/or looseness of screws.
If any abnormalities are found, contact the supplier immediately.
Checking the model
Extension cable
×2
MABS technical document
Safety precautions
Advanced preparation
Product check
Structures
Installation/Wiring
Control/Operation
Maintenance/Inspection
Troubleshooting
Appendix
IB-E06F-M1 settings
Power
Hi
Low
Node ID
NS
ERR A
IN 3
IN 2
IN 1
1.MA-DIR
OUT 1
OUT 2
OUT 3
OUT 4
OUT 5
0V
24V
OUT1
OUT2
OUT3
OUT4
OUT5
COM
COM
IN3
IN2
IN1
RemoteIN
SensorA
SensorB
RemoteOUT
MOTOR B(M2)
MOTOR A(M1)
0V
ALM
SEN
24V
24V
SEN
ALM
0V
2.MB-DIR
3.MA-SYN
4.MB-SYN
LAN 1
SEN A
RUN A
ERR B
LAN 2
SEN B
RUN B
LAN 1
LAN 2
R
EtherNet/IP
IB-E06F-M1
MS
STS
Serial#:0x16600001
NXP:1005, R8C:8108
IB-E06F-N-UL-M1
OUTPUT
:
24Vp-p, 2.5A×2(AXES)
INPUT
:
24V , 5.8A
3Ø, 165Hz(0Hz
〜
179Hz)
123
4
5
678
9A
B
C
DE
F0
123
4
5
678
9A
B
C
DE
F0
T2
T26
T7 T28 T27
T2
LED32
LED323
LED304
LED303
LED302
LED301
R347
R348
SW402
T8
T25
SW401
LED318
LED319
SW403
LED309
RG301
4
1
LED403
LED31
D308
D307
D306
ED312
322
320
310
401
Power
Hi
Low
Node ID
NS
ERR A
IN 3
IN 2
IN 1
1.MA-DIR
OUT 1
OUT 2
OUT 3
OUT 4
OUT 5
0V
24V
OUT1
OUT2
OUT3
OUT4
OUT5
COM
COM
IN3
IN2
IN1
RemoteIN
SensorA
SensorB
RemoteOUT
MOTOR B(M2)
MOTOR A(M1)
0V
ALM
SEN
24V
24V
SEN
ALM
0V
2.MB-DIR
3.MA-SYN
4.MB-SYN
LAN 1
SEN A
RUN A
ERR B
LAN 2
SEN B
RUN B
LAN 1
LAN 2
R
EtherNet/IP
IB-E06F-M1
MS
STS
Serial#:0x16600001
NXP:1005, R8C:8108
IB-E06F-P-UL-M1
OUTPUT
:
24Vp-p, 2.5A×2(AXES)
INPUT
:
24V , 5.8A
3Ø, 165Hz(0Hz
〜
179Hz)
123
4
5
678
9A
B
C
DE
F0
123
4
5
678
9A
B
C
DE
F0
T2
T26
T7 T28 T27
T2
LED32
LED323
LED304
LED303
LED302
LED301
R347
R348
SW402
T8
T25
SW401
LED318
LED319
SW403
LED309
RG301
4
1
LED403
LED31
D308
D307
D306
ED312
322
320
310
401
IB-E06F-N-UL-M1
IB-E06F-P-UL-M1
〈
Product label details
〉
Model
Ref.
Date
Serial
IP
V
Poids
W
m/min
Service
ITOH DENKI EUROPE SAS
MABS-K9-40A-C2-P01
07/22
123456789
54
24VDC
14.5Kg
112W
90m/min
00
□
A
□
Original notice - U1.1