38
Input/output circuit
CN301
IB-E06F-M1 wiring
■
Set the voltage used for remote input within the range of 18 [V]DC to 30 [V]DC.
■
Connect the COMMON terminal for remote input and remote output separately.
■
Set the voltage used for remote output within the range of 18 [V]DC to 30 [V]DC.
■
The maximum output current value for remote output is 1 [A] on #1 and #2, and 200 [mA]
on #3 to #5.
■
When outputting the remote output to the relay coil, use surge protector devices, or
perform surge protection measures using diodes.
Failure to perform surge protection measures could result in damage to the signal output
terminal, if counter electromotive voltage is generated when switching the output signal.
#1
#6
#1 RemoteOUT1
#2 RemoteOUT2
#3 RemoteOUT3
#4 RemoteOUT4
#5 RemoteOUT5
#6 COMMON
#1
#4
#1 RemoteIN1
#2 RemoteIN2
#3 RemoteIN3
#4 COMMON
【
Remote input (CN301)
】
734-264 (WAGO)
Maximum allowable current:10[A]
・
Set the NPN/PNP signal switching for remote input using COMMON.
Connect the positive pole to COMMON at the time of NPN input, and 0V to
COMMON at the time of PNP input.
COMMON is common among RemoteIN1 to 3.
CN302
【
Remote output (CN302)
】
734-266 (WAGO)
・
Set the NPN/PNP signal switching for remote output using COMMON.
Connect 0V to COMMON at the time of NPN output, and the positive pole to
COMMON at the time of PNP output.
Note that COMMON is common among RemoteOUT1 to 5.
Remote input interface circuit diagram
Remote output interface circuit diagram
GND
CDGND
VCC
LED301
1
1
2
3
4
5
6
4
3
2
CN301
1
2
1
2
1
2
1
3
4
VCC
INPUT1
INPUT2
INPUT3
OUTPUT1
3
4
3
4
5.1K 1/4W
5.1K 1/4W
5.1K 1/4W
2
3
4
WAGO
734-264
CN302
WAGO
734-266
VCC
LED302
1
4
3
10 1/3W
2
OUTPUT2
VCC
LED303
1
4
3
2
OUTPUT3
10 1/3W
10 1/3W
VCC
LED304
1
4
3
2
OUTPUT4
VCC
LED305
1
4
3
2
OUTPUT5