Commands
Copyright © Itech Electronic Co., Ltd.
30
Chapter7 Commands
FETCh[:SCALar]:ENERgy[:ACTive][:SUM]?
This command is used to read the latest pre-processing the sum of positive watt
hour and negative watt hour.It will not affect the device setting values and will
not trigger a new measurement operation.It only requires to get the latest
available value that has been measured.
Command Syntax
FETCh[:SCALar]:ENERgy[:ACTive][:SUM]?
Returned value
<NR2>
MEASure[:SCALar]:ENERgy[:ACTive][:SUM]?
This command will trigger the measurement operation to get a real-time sum of
positive watt hour and negative watt hour.
Command Syntax
MEASure[:SCALar]:ENERgy[:ACTive][:SUM]?
Returned value
<NR2>
FETCh[:SCALar]:ENERgy[:ACTive]:POSitive?
This command is used to read the latest pre-processing positive watt hour.It will
not affect the device setting values and will not trigger a new measurement
operation. It only requires to get the latest available value that has been
measured.
Command Syntax
FETCh[:SCALar]:ENERgy[:ACTive]:POSitive?
Returned value
<NR2>
MEASure[:SCALar]:ENERgy[:ACTive]:POSitive?
This command will trigger the measurement operation to get a real-time positive
watt hour.
Command Syntax
MEASure[:SCALar]:ENERgy[:ACTive]:POSitive?
Returned value
<NR2>