Trigger Commands
Copyright © Itech Electronic Co., Ltd.
51
Command Syntax
TRIGger:IMMediate
Parameters
None
Relevant command
*TRG TRIG:SOUR
TRIGger:SOURce <state>
This command is used to select trigger source.Trigger source modes are as
below.When execute *RST command,trigger source should be set in MANUAL
mode.
Parameters Function description
IMMediate
BUS
Sending TRIG:IMM or *TRG command will create a trigger
signal.
EXTernal
External clock trigger mode
VOLTage
Set input voltage source as a trigger signal
CURRent
Set input current source as a trigger signal
Command Syntax
TRIGger:SOURce <state>
Parameters
IMMediate|BUS|EXTernal|VOLTage|CURRent
Query Syntax
TRIGger:SOURce?
TRIGger:SLOPe <state>
This command is used to set the trigger slope,parameters could be rising
edge/descending dege/any edge.
Command Syntax
TRIGger:SLOPe <state>
Parameters
POSitive|NEGative|ANY
Query Syntax
TRIGger:SLOPe?
TRIGger:VOLTage:LEVel <level>
This command is used to set the voltage trigger level when Voltage selected as