Status Register Commands
Copyright © Itech Electronic Co., Ltd.
9
STATus:QUEStionable[:EVENt]?
This command is used to read the value of query event register.Power meter
will return a decimal number which is the binary weighted sum of each bits of
register.All these bits value is latched and will be cleared after executing this
command.
Query syntax
STATus:QUEStionable[:EVENt]?
Parameters
None
Returned value
<NR1>
Related commands
STATus:QUEStionable:ENABle
STATus:QUEStionable:CONDition?
This command is used to read the value of query condition register to get the
power meter’s status,such as OCPeak/OCRMS/OV/OP/OT.
Query syntax
STATus:QUEStionable:CONDition?
Paramters
None
Returned value
<NR1>
STATus:QUEStionable:ENABle<NRf>
This command is used to set the value of query event enable registers.This
register is a mask of enabling specific bits from the questionable event register
to set the questionable summary bit(ques) of the status byte register.
Command syntax:
STATus:QUEStionable:ENABle <NRf>
Parameters:
0
~
65535
Power-on value
Refer to *PSC command
Example
STATus:QUEStionable:ENABle 16