4-44
Getting Started
Chapter 4
Card Lift
The symbol
is indicated by the column pointer.
This menu is identical with the menu "Column change".
As many line values are displayed as programmed in the menu item "Card specific
parameters - Number of lines".
Hint
The line height can only be entered if you have selected the
values "00" or "Co" in the menu "Card specific parameters". See
Appendix A "Define your own card format".
If you have selected a standard card format, these values cannot
be changed.
Definitions:
D1
D2
D3
.
D1 = 00 to XX:
→
indicates the current line, starting with D1=00 and the
corresponding line value (D2 and D3).
D1 = 00 indicates the bottom line of the card.
D1 = 01 indicates the clocking field at a graphic recorder and
the lowest clocking line at a standard recorder.
D2, D3 = XX:
→
Line height in mm, value given by the card format selected.
Accuracy: 1/10 mm.
Example:
D1 = 01 D2 = 11 D3 = 0.0
→
D1 = 1. line = clocking field
→
D2 and D3 = line height of the clocking field = 110 mm
Units destined for North America are pre-programmed with
bottom line = 26 mm, clocking field = 110mm
(consequence of setting card format no. 29)
.
The lines can be changed and the values checked by pressing "
E
".
If you want to continue with the next menu item, press "
S
".