4-24
Getting Started
Chapter 4
Print out all Parameters Programmed
The recorder offers the possibility to print out all parameters values on an empty time
card. Any empty card can be used.
Minimum dimension of the card:
210 x 86 mm (L x W)
We recommend a card length of 230 mm.
You can print out the parameters together with programming the recorder or
afterwards. After the programming you have to insert an empty card and select the
menus again. For this it is indispensable to once again call up the programming
routine (1888).
Attention
We recommend to use a card with the same dimensions as the
time card used normally.
If another card is taken it may happen that the printer overprints
the card edge and directly prints upon the printing beam. This
could damage the printer head.
The minimum card length has to be 210 mm. Don't fall below the
indicated dimensions.
The parameter values will be printed out when a menu item is left. If you insert an
empty card and press "S" all values programmed in the last menu will be printed out.
The print out begins with the menu item "Card specific parameters". The menu items
"National identification" and "Summer- /normaltime" cannot be printed.
The card must be turned from the menu item "Ribbon colour change" on.
You can find a complete protocol print out at the end of this chapter
(page 4-60/4-61).
Proceeding
1.
Insert empty time card.
2.
Press time card slightly down after menu item has been finished (like at a
normal clocking)
and
3.
press "
S
".
Column pointer changes to the next menu symbol (menu item) and the values
of the last menu item are printed out.
4.
Repeat steps 2 and 3 with the card remaining in the recorder. Remove card
after programming has been finished.