7-4
Maintenance
Chapter 7
1.
The time recorder is switched on.
2.
Press "
R
" and "
E
" simultaneously and keep these keys pressed for 1 second.
→
Column pointer moves to the park position right of the card funnel.
3.
Press the locking straps on the left and right side of the card funnel slightly
towards the recorder and swing out the programming panel.
4.
Lift up and remove the ribbon cassette.
Warning!
Depending on use, the printer head may be very hot.
Touching the printer head could cause burns.
5.
Insert new ribbon cassette and push slightly down.
Tighten the new ribbon by winding the red ribbon tightening knob in the
direction indicated by the arrow on the cassette. Position the free guide of the
ribbon in the direction of the printer head.
Make sure that the ribbon guide is inserted in front of the printer head and that
the ribbon is not twisted or creased.
The ribbon cassette must engage into the left and right locking straps.
6.
Check that the ribbon fits between the printer head and the ribbon guide.
Tighten the ribbon again.
7.
Swing in the programming panel.
Press "
R
" and "
E
" once again, see step 2.
→
The column pointer moves back to initial position.
8.
Close the time recorder.
Cleaning the Time Recorder
The main problem is dust on electronic components.
In order to maintain the physical appearance of the time recorder, the cover must be
occasionally cleaned.
The cleaning intervals depend on the operating conditions and the location.
When cleaning the time recorder with cloths, please observe the following
recommendations:
•
Use only rags moistened with water or a soap-free detergent.
•
Do not use any detergent spray or wet rags.
•
Use only soft detergents without solvents of any kind.
•
Make sure to thoroughly dry all components after cleaning.