6-2
Trouble Shooting
Chapter 6
Error Messages
Any error at the time recorder is indicated by a combination on the display. If the
problem cannot be solved, please contact your local dealer or e-mail us at:
To avoid any confusion with the date, all error messages begin with the letter E.
Display
Reason
What can be done
P-Module, Error in resident
memory.
→
Punching at the recorder
is no longer possible.
Switch unit off and on.
If the error message is still
displayed, the P-Module has
to be changed.
Save all data before.
After change of the P-module
a complete reset must be
carried out.
Load the saved data into the
recorder.
Error not corrected, change
PC-board
RTC-module, error in real
time clock component.
→
Punching at the recorder
is no longer possible.
Switch recorder off and on.
If the error message is still
displayed, first carry out a
complete reset.
Error not corrected, change
PC-board. Do not change
only the RTC-module as it is
a SMD component.
Error in synchronization of
the card lift, mechanical
error.
→
Punching at the recorder
is no longer possible.
Switch recorder off and on.
If the error message is still
displayed check all
components of the card lift
for soiling and clean if
necessary. All parts must be
moveable smoothly.
Check all parts for wear. If
the transport spindle or the
bottom line controller is
defective, change the
complete card lift unit.
Check lines and connections
and repair if necessary.
Check step-motor and
function and change if