Chapter 3
Time Recorder Installation 11
Connect wiring for audible signal circuit control
(Signal circuit / Check of individuals
→
only if required.
→
low power signal output: 15 V DC, 50mA
This connection is not polarity sensitive.
Connect wiring for synchronized clock option
→
only if the recorder is equipped with the option module "MASTER CLOCK".
→
fused output rated at 12 V, max. 50 mA,
This connection is not polarity sensitive.
Connect an optional battery pack for printer operation during a power failure.
Attention
This connection is polarity sensitive!
Connect impulse lines for slave clocks connection.
→
only if recorder is equipped with option module slave clock function"
→
unipolar and bipolar impulses, 12 V - 60 V, 2 - 10 mA.
This connection is not polarity sensitive.
The Installation is now finished.
To program the time recorder see chapter 4 "Getting Started".
If the recorder is to be programmed at a later date, insert the front cover and close
the recorder.