Chapter 3: Troubleshooting & Testing
Mechanical, electrical, and
electronic diagnostics
No power to the FlexJet
If you should power the machine up
and nothing happens, check the fuse in
the power entry module (
Figure 39a
) on
the back of the right side cover.
1.
To check or replace the fuse start
by flipping the fuse door down
(
Figure 39b
).
2.
Pull out the red fuse holder. (
Figure
39c
&
d
).
3.
Check or replace fuses as needed.
(
Figure 39e
).
4.
Use only 5A, 250V, 5x20mm slow
blow fuses for replacement.
Figure 39.
Replacing the fuse.
a
b
c
d
e
The fuse holder is universal. so it
doesn’t matter which way it goes
back in. Make sure the flat end is
facing out.