Goodrive3000 series medium voltage VFD Goodrive3000 PWM rectifier
-55-
Fault
code
Type of fault
Possible causes
Countermeasures
CE
485 communication
fault
Improper setting of baud rate
Error with serial communication
Long period of communication
interrupt
Set appropriate baud rate
Press STOP/RST to reset and
contact the service department
Check the wiring of the
communication interfaces
E-CAN
CANopen
communication fault
CANopen communication offline
Wrong parameters setting
Check the parameter setting and
external wiring and restore
E-NET
Ethernet
communication fault
Communication offline
Wrong parameters setting
Please check the parameter
settings and external wiring
OL
Rectifier overload
The load exceeds the range
Adjust the load or change another
rectifier
EEP
EEPROM operation
fault
Read/write fault of the control
parameters
Damage to DPRAM chip
Press STOP/RST to reset
Ask for service
TbE
Contactor fault
Damage to the contactor
Contactor auxiliary abnormal
Interference
Check contactor
Check the contactor auxiliary
contact
Check the external environment
to exclude interference
dF_CE
DSP-FPGA
communication fault
Excessive electromagnetic
interference
The quality of electric power is too
low
FPGA chip damage
DSP chip damage
View the unit state and ensure
FPGA is damaged or not
Contact with us
EF
External fault
SI external fault input terminals
action
Check the external device input
dIS
Rectifier disabled
The digital output function of the
system: rectifier enabled but the
digital terminal does not act
Press the corresponding digital
terminal and enter P5 function
group to cancel the function
UPE
Upload fault
Keyboard line is disconnected or
offline
Keyboard line is too long or
interfered
Circuit fault to the keypad or main
Check the environment and
eliminate the interference
Change the hardware and ask for
service
Change the hardware and ask for