![INVT GD3000-01-055G-12 Operation Manual Download Page 199](http://html1.mh-extra.com/html/invt/gd3000-01-055g-12/gd3000-01-055g-12_operation-manual_2085697199.webp)
Goodrive3000 series medium voltage VFD Goodrive3000 inverter
-194-
Function
code
Name
Description
Setting range
Default Modify
P01.23
Start delay time 0.0
–
60.0s
0.0
–60.0
0.0s
○
P01.24
Delay time of
stop speed
0.0
–
100.0s
0.0
–100.0
0.0s
○
P01.25
0Hz output
selection
0: Output without voltage
1: Output with voltage
2: Output according to DC braking
current at stopping
0
–2
0
○
P02 group
––Motor 1 parameters
P02.00
Motor 1 type
0: Asynchronous motor
1: Reserved
0
–1
0
◎
P02.01
Asynchronous
motor 1 rated
power
0.1
–3000.0kW
0.1
–3000.0
Depends
on model
◎
P02.02
Asynchronous
motor 1 rated
frequency
0.01Hz
–P00.03 (Max. frequency)
0.01
–P00.03
50.00Hz
◎
P02.03
Asynchronous
motor 1 rated
speed
1
–
36000rpm
1
–36000
Depends
on model
◎
P02.04
Asynchronous
motor 1 rated
voltage
0
–
4000V
0
–4000
Depends
on model
◎
P02.05
Asynchronous
motor 1 rated
current
0.8
–
6000.0A
0.8
–6000.0
Depends
on model
◎
P02.06
Asynchronous
motor 1 stator
resistor
0.001
–65.535Ω
0.001
–65.535
Depends
on model
○
P02.07
Asynchronous
motor 1 rotor
resistor
0.001
–65.535Ω
0.001
–65.535
Depends
on model
○
P02.08
Asynchronous
motor 1 leakage
inductance
0.1
–
6553.5mH
0.1
–6553.5
Depends
on model
○
P02.09
Asynchronous
motor 1 mutual
0.1
–
6553.5mH
0.1
–6553.5
Depends
○