Goodrive3000 series medium voltage VFD Goodrive3000 inverter
-141-
Function
code
Name
Description
Setting range
Default
effective.
LED tens: Frequency control
selection
0: Only effective when P00.06=0 or
P00.07=0
1: Effective for all frequency setting
manners
2: Ineffective for multi-step speed
when multi-step speed has the
priority
LED hundreds: Action selection
during stopping
0: Effective setting
1: Effective during running, cleared
after stopping
2: Effective during running, cleared
after receiving the stop command
LED thousands:
∧
/
∨
and digital
potentiometer integral function
0: Effective integral function
1: Ineffective integral function
Set the control functions of the keypad.
Function
code
Name
Description
Setting range
Default
P08.43
Integral ratio of the
keypad
potentiometer
0.01
–10.00s
0.01
–10.00
0.10s
P08.44
UP/DOWN terminal
control
0x000
–0x221
LED ones: Frequency control
selection
0: UP/DOWN terminal setting
effective
1: UP/DOWN terminal setting
ineffective
LED tens: Frequency control
selection
0: Only effective when P00.06=0 or
000
–221
0x000