![INVT CHV160 Operation Manuals Download Page 91](http://html1.mh-extra.com/html/invt/chv160/chv160_operation-manuals_2085685091.webp)
SHENZHEN INVT ELECTRIC CO., LTD. CHV160 Operation Manual
91
Function
Code
Name
Detail Parameter Description
Setting
Range
Defaul
t
Modifi
cation
LCD Display Serial
No.
P1.09
Beginning
Frequency of
braking stop
0.00
10.00Hz
0.00
10.00
0.00H
z
Brake start
freq
28.
P1.10
Waiting time of
braking stop
0.0
50.0s
0.0
50.0
0.0s
Brake wait
time
29.
P1.11 DC braking current
0.0
150.0%
0.0
150.0
0.0%
Brake
current
30.
P1.12
DC braking time
0.0
50.0s
0.0
50.0
0.0s
Brake time
31.
P1.13
Dead time between
forward and
reverse
0.0
3600.0s
0.0
3600.0
0.0s
F/R dead
time
32.
P1.14
Act if operating
Frequency is less
than lower
frequency limit
(Valid if the lower
limit is more than
0)
0: Run at lower freq limit
1
Stop
2
Dormancy & stand-by
0
2
0
Lower freq
limit
33.
P1.15
Power-back restart
option
0
Restart disabled
1
Restart enabled
0
1
0
Power
restart
34.
P1.16
Restart waiting
time
0.0
3600.0s
0.0
3600.0
0.0s
Waiting time 35.
P2 Group Motor Para
P2.00
Inverter model
0
Constant torq
1
Variable torq
0
1
Set by
model
Inverter
model
36.
P2.01
Motor rated
frequency
0.01Hz
P0.07
0.01
P0.07
50.00
Hz
Rated
frequency
37.
P2.02
Motor rated speed
0
36000rpm
0
36000
1460r
pm
Rated speed 38.
P2.03 Motor rated voltage
0
440V
0
440 380V
Rated
voltage
39.
P2.04 Motor rated current
0.1
1000.0A
0.1
1000.0
Set by
model
Rated
current
40.
P2.05
Motor rated power
0.4
900.0kW
0.4
900.0
Set by
model
Rated power 41.
P2.06
Motor stator
resistance
0.001
65.535
0.001
65.535
Set by
model
Stator resist 42.
P2.07
Motor rotor
resistance
0.001
65.535
0.001
65.535
Set by
model
Rotor resist
43.
P2.08
Motor stator/rotor
inductance
0.1
6553.5mH
0.1
6553.5
Set by
model
Stat/rot
induct
44.
P2.09
Mutual inductance
of motor
stator/rotor
0.1
6553.5mH
0.1
6553.5
Set by
model
S/R mut
induct
45.