Chapter 4: Menu reference
88
CDC4 Door Controller Installation and Programming Manual
Programming mapped outputs
You can configure its settings in the Panel data window > Outputs list.
Assigned RASs tab
Keypads and readers attached to one of the door controller local buses must be
assigned to CDC4 on the Assigned RAS tab of the Expander form.
Select the appropriate keypad and click Browse
“...” to open the Assigned RAS
form.
The following settings are available.
Name
When a RAS
is created, it is given the default name “RAS <n>”, where <n> is the
RAS number. Enter this menu to edit the current name.
RAS type
This read-only field shows the format used by the bus for the selected RAS. See
the “Bus options” section on page 84.
RAS model
If the Bus format field is set to ATS, then the RAS model can be selected from
the following:
• ATS1190/1192: ATS smart card reader
• ATS1197: ATS smart card reader with keypad
• ATS1160N/ATS1161N: ATS Mifare DESFire & EV1 reader (with keypad)
• ATS1151: ATS keypad with 3 LED
• ATS1156: ATS magstripe card reader with keypad
• ATS1155: ATS heavy-duty keypad
• ATS1170: ATS Wiegand/reader interface
• ATS118x: ATS smart card readers
Aperio EAC
If the Bus format for the bus is set to Aperio, then enter the Aperio EAC
(Electronic Access Control) number in this field. Values can range from 1 to 255.
Poll
Set the option to On to poll the device.
Remove
Click Remove to delete the selected device.
Summary of Contents for CDC4
Page 1: ...CDC4 Door Controller Installation and Programming Manual P N 466 5478 REV D ISS 29OCT19 ...
Page 86: ...Chapter 3 Programming 80 CDC4 Door Controller Installation and Programming Manual ...
Page 120: ...Chapter 4 Menu reference 114 CDC4 Door Controller Installation and Programming Manual ...
Page 136: ...130 CDC4 Door Controller Installation and Programming Manual ...