Appendix A: Door controller events
118
CDC4 Door Controller Installation and Programming Manual
Name
Description
Input Output
Door enabled
Door is enabled
No
Yes
Door fire override
Secondary override is active
Yes
Yes
Door forced
Door Contact is open with no valid door command
Yes
No
Door interlock
Interlock input(s) are active
Yes
Yes
Door interlock override [1] If the interlock has been overridden
Yes
Yes
Door keypad duress [3]
Duress PIN code entered at door keypad
Yes
No
Door LED1 [3]
LED 1 output is active
Yes
Yes
Door LED2 [3]
LED 2 output is active
Yes
Yes
Door lock
Lock output is de-activated to lock the door
No
Yes
Door low security inside
[2]
Card and PIN required to access at the
“IN” reader Yes
Yes
Door low security outside
[2]
Card and PIN required to access at the “OUT”
reader
Yes
Yes
Door open
Door Open command is active (to unlock / start
shunt)
Yes
Yes
Door open too long
Door Contact is open after shunt timer has expired Yes
No
Door override
The override schedule assigned to the door is valid Yes
Yes
Door override inhibit [1]
The override schedule is inhibited
Yes
Yes
Door random bit
An event is generated at random when the door is
accessed
Yes
No
Door reader disabled [4]
Reader is disabled
Yes
Yes
Door reader enabled
Reader is enabled
No
Yes
Door secure
When the door is LOCKED and the door is
CLOSED.
Yes
No
Door shunt warning
Shunt warning timer is running
Yes
No
Door shunting
Shunt timer is running
Yes
Yes
Door unlock
Lock output is active to unlock the door
Yes
Yes
Door reader fault [3]
Fault detected on reader (Comms / tamper / etc.)
Yes
No
Door lock fault [3]
Cable tamper / fault detected on lock output wiring Yes
No
[1]
Denotes rule can only be activated as a result of another door macro.
[2]
Denotes rule can only be activated as a result of another door macro and the function of the
door (the macro input is always true if the function is set in the programming)
[3]
Denotes the event is currently not enabled.
[4]
User with the
“Privilege” attribute set can override the “Reader disabled” function.
Table 11: Other macro event descriptions
Name
Description
Input Output
Area access
Area in access (99 events, 1 per area)
Yes
No
Area alarm
Input(s) in alarm in area (99 events, 1 per area)
Yes
No
Summary of Contents for CDC4
Page 1: ...CDC4 Door Controller Installation and Programming Manual P N 466 5478 REV D ISS 29OCT19 ...
Page 86: ...Chapter 3 Programming 80 CDC4 Door Controller Installation and Programming Manual ...
Page 120: ...Chapter 4 Menu reference 114 CDC4 Door Controller Installation and Programming Manual ...
Page 136: ...130 CDC4 Door Controller Installation and Programming Manual ...