Chapter 1: Installation
26
CDC4 Door Controller Installation and Programming Manual
Auxiliary power terminals
Connect the AUX POWER +12 and AUX POWER − output terminals to devices
that require 12V DC power, such as detectors. Three sets of auxiliary power
output terminals are provided.
Note:
Door controller system design should consider the fuse partitioning and
load limitations specified in Output fusing and user current draw
Siren
Connect the OUT S+ and OUT S
− terminals to an 8 Ω siren speaker or two 8 Ω
siren speakers in parallel. Alternatively, connect a device requiring 12 VDC
power.
The OUT S+ terminal is always powered. The OUT S- terminal is switched
according to the Siren SW settings. A 1
kΩ 1/4 W resistor (supplied) should be
connected across the OUT S+ and OUT S
− terminals:
• At the load side when driving digital inputs or other light loads.
• At the terminals when no device is connected.
Note:
Door controller system design should consider the fuse partitioning and
load limitations specified in Output fusing and user current draw
Caution:
The siren type must be configured correctly in Downloader. Specifying
a siren type of DC Volts when there is an 8 Ω siren connected to the CDC4 may
damage the siren.
System data bus
Use 2-pair twisted shielded data cable such as WCAT52 or WCAT54 to connect
the CDC4 door controller to the system data bus 1 of the Advisor Advanced
control panel.
For more information on system data bus connection, see
Advisor Advanced
ATSx500A(-IP) Installation and Programming Manual
.
Local data buses
CDC4 can have up to 16 remote keypad/reader devices such as keypads, card
readers, and arming stations each bus (local data bus). CDC4 can also have up
to 15 remote expanders on bus 1 and up to 16 remote expanders on bus 2.
Each bus supports protocols other than ATS, namely OSDP v2 (Open
Supervised Device Protocol), SALLIS by SALTO, and Aperio. The protocol to be
used on each bus can be independently configured.
Note:
Devices connected to the buses and powered by the door controller must
comply with “Output fusing and user current draw” on page 38.
Summary of Contents for CDC4
Page 1: ...CDC4 Door Controller Installation and Programming Manual P N 466 5478 REV D ISS 29OCT19 ...
Page 86: ...Chapter 3 Programming 80 CDC4 Door Controller Installation and Programming Manual ...
Page 120: ...Chapter 4 Menu reference 114 CDC4 Door Controller Installation and Programming Manual ...
Page 136: ...130 CDC4 Door Controller Installation and Programming Manual ...