Chapter 2: System functions
CDC4 Door Controller Installation and Programming Manual
45
Operating modes
The door controller can be configured in the following ways depending on your
current system and access requirements:
• Standard mode: The door controller only communicates with the control
panel.
• Extended mode: In this mode, management software has a direct IP
connection to CDC4.
Note:
The operating mode can only be set for all connected door controllers
during the initial installation of the Advisor Advanced panel. See
Advisor
Advanced ATSx500A(-IP) Installation and Programming Manual
for more
information.
The limits for users and other entities vary according to the operating mode, as
shown in Table 6 below.
Table 6: CDC4 limits per mode
Standard
Extended
Doors
4
8
Users
64532
64532
Door groups
128
10,000
Schedules
24
2,000
Sub schedules
4
8
Holiday types
8
8
Card bit length
56
56
History event buffer
50,000
50,000
The modes are described in more detail in the following sections.
Standard mode
Standard mode can be used for direct upgrade of ATS125x four-door controller
with minimal changes. In addition to access control, CDC4 provides alarm control
functionality in conjunction with an Advisor Advanced panel.
CDC4 is polled as an expander on the first Advisor Advanced system bus.
Summary of Contents for CDC4
Page 1: ...CDC4 Door Controller Installation and Programming Manual P N 466 5478 REV D ISS 29OCT19 ...
Page 86: ...Chapter 3 Programming 80 CDC4 Door Controller Installation and Programming Manual ...
Page 120: ...Chapter 4 Menu reference 114 CDC4 Door Controller Installation and Programming Manual ...
Page 136: ...130 CDC4 Door Controller Installation and Programming Manual ...